Literature DB >> 8888589

B1-insensitive, single-shot localization and water suppression.

R A de Graaf1, Y Luo, M Garwood, K Nicolay.   

Abstract

A technique for single-shot, localized, water-suppressed in vivo 1H NMR with high immunity to B1 inhomogeneities is described. The single-shot localization is based on complete outer-volume suppression which is achieved with optimized, adiabatic BIR-4 pulses in combination with BO gradient modulation. B1-insensitive water suppression is achieved with BISTRO, a train of selective adiabatic full-passage pulses interleaved with BO gradient crushers. Computer simulations based on the Bloch equations, experimental images of the localized volume, and in vivo 1H spectroscopy experiments demonstrate the excellent spatial localization and water suppression.

Entities:  

Mesh:

Year:  1996        PMID: 8888589     DOI: 10.1006/jmrb.1996.0152

Source DB:  PubMed          Journal:  J Magn Reson B        ISSN: 1064-1866


  28 in total

1.  Measurement of unidirectional Pi to ATP flux in human visual cortex at 7 T by using in vivo 31P magnetic resonance spectroscopy.

Authors:  Hao Lei; Kamil Ugurbil; Wei Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-11       Impact factor: 11.205

2.  Multimodal neuroimaging provides a highly consistent picture of energy metabolism, validating 31P MRS for measuring brain ATP synthesis.

Authors:  Myriam M Chaumeil; Julien Valette; Martine Guillermier; Emmanuel Brouillet; Fawzi Boumezbeur; Anne-Sophie Herard; Gilles Bloch; Philippe Hantraye; Vincent Lebon
Journal:  Proc Natl Acad Sci U S A       Date:  2009-02-20       Impact factor: 11.205

3.  Myelin vs axon abnormalities in white matter in bipolar disorder.

Authors:  Kathryn E Lewandowski; Dost Ongür; Sarah H Sperry; Bruce M Cohen; Selma Sehovic; Jacqueline R Goldbach; Fei Du
Journal:  Neuropsychopharmacology       Date:  2015-03-13       Impact factor: 7.853

4.  Rapid and simultaneous measurement of phosphorus metabolite pool size ratio and reaction kinetics of enzymes in vivo.

Authors:  Sang-Young Kim; Wei Chen; Dost Ongur; Fei Du
Journal:  J Magn Reson Imaging       Date:  2017-05-08       Impact factor: 4.813

5.  Water removal in MR spectroscopic imaging with L2 regularization.

Authors:  Liangjie Lin; Michal Považan; Adam Berrington; Zhong Chen; Peter B Barker
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

6.  Abnormalities in High-Energy Phosphate Metabolism in First-Episode Bipolar Disorder Measured Using 31P-Magnetic Resonance Spectroscopy.

Authors:  Fei Du; Cagri Yuksel; Virginie-Anne Chouinard; Polly Huynh; Kyle Ryan; Bruce M Cohen; Dost Öngür
Journal:  Biol Psychiatry       Date:  2017-04-07       Impact factor: 13.382

7.  Brain high-energy phosphates and creatine kinase synthesis rate under graded isoflurane anesthesia: An in vivo (31) P magnetization transfer study at 11.7 tesla.

Authors:  Andrew Bresnen; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2014-02-12       Impact factor: 4.668

Review 8.  In vivo NMR studies of neurodegenerative diseases in transgenic and rodent models.

Authors:  In-Young Choi; Sang-Pil Lee; David N Guilfoyle; Joseph A Helpern
Journal:  Neurochem Res       Date:  2003-07       Impact factor: 3.996

9.  In vivo proton MRS to quantify anesthetic effects of pentobarbital on cerebral metabolism and brain activity in rat.

Authors:  Fei Du; Yi Zhang; Isabelle Iltis; Malgorzata Marjanska; Xiao-Hong Zhu; Pierre-Gilles Henry; Wei Chen
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

10.  Two-dimensional J-resolved LASER and semi-LASER spectroscopy of human brain.

Authors:  Meijin Lin; Anand Kumar; Shaolin Yang
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.