Literature DB >> 8858722

A pencil beam algorithm for proton dose calculations.

L Hong1, M Goitein, M Bucciolini, R Comiskey, B Gottschalk, S Rosenthal, C Serago, M Urie.   

Abstract

The sharp lateral penumbra and the rapid fall-off of dose at the end of range of a proton beam are among the major advantages of proton radiation therapy. These beam characteristics depend on the position and characteristics of upstream beam-modifying devices such as apertures and compensating boluses. The extent of separation, if any, between these beam-modifying devices and the patient is particularly critical in this respect. We have developed a pencil beam algorithm for proton dose calculations which takes accurate account of the effects of materials upstream of the patient and of the air gap between them and the patient. The model includes a new approach to picking the locations of the pencil beams so as to more accurately model the penumbra and to more effectively account for the multiple-scattering effects of the media around the point of interest. We also present a faster broad-beam version of the algorithm which gives a reasonably accurate penumbra. Predictions of the algorithm and results from experiments performed in a large-field proton beam are presented. In general the algorithm agrees well with the measurements.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8858722     DOI: 10.1088/0031-9155/41/8/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  78 in total

1.  Aspects of medical physics of Med-Austron.

Authors:  U Haverkamp
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

2.  Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques.

Authors:  Wei Liu; Yupeng Li; Xiaoqiang Li; Wenhua Cao; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

3.  A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations.

Authors:  Pablo P Yepes; Dragan Mirkovic; Phillip J Taddei
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

4.  Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy.

Authors:  Yang-Kyun Park; Gregory C Sharp; Justin Phillips; Brian A Winey
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

5.  Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields.

Authors:  Harald Paganetti
Journal:  Phys Med Biol       Date:  2006-05-17       Impact factor: 3.609

6.  Dosimetric accuracy of planning and delivering small proton therapy fields.

Authors:  Bryan Bednarz; Juliane Daartz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2010-11-19       Impact factor: 3.609

7.  Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code.

Authors:  K Parodi; A Ferrari; F Sommerer; H Paganetti
Journal:  Phys Med Biol       Date:  2007-05-17       Impact factor: 3.609

8.  A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.

Authors:  David C Westerly; Xiaohu Mo; Wolfgang A Tomé; Thomas R Mackie; Paul M DeLuca
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

9.  Comparison of intensity modulated x-ray therapy and intensity modulated proton therapy for selective subvolume boosting: a phantom study.

Authors:  R T Flynn; D L Barbee; T R Mackie; R Jeraj
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

10.  Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.