Literature DB >> 8854261

Clinical application of the computer picture archiving and communicating system to stereotactic radiosurgery.

T Shiga1, H Shirato, Y Kikuchi, T Nishioka, T Kitahara, S Terae, N Nishiyama, X Bo, K Miyasaka.   

Abstract

Stereotactic radiosurgery, a rapidly evolving technology, provides precise high-dose irradiation to brain lesions and tumors. A new method using digital subtraction angiographic images of a personal computer-image display terminal interfaced to our picture archiving and communication system (PACS) performs measurements and calculations of the coordinates of the location of the center of the lesion to be treated. The time required to calculate the coordinates was performed by three methods: hand calculation, digitizer method, and PACS method. These three coordinates were compared in 10 cases. The hand calculation method required approximately 50 minutes, the digitizer method required approximately 10 minutes, and the PACS method approximately 3 minutes. The difference is statistically significant (P < .001). The three methods were equally accurate. This type of PACS application using inexpensive personal computers interfaced more directly to a PACS is an emerging trend that facilitates wider access to images and to manipulating them for specialized applications.

Entities:  

Mesh:

Year:  1996        PMID: 8854261     DOI: 10.1007/bf03168606

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  6 in total

1.  Clinical experience--16 months of HU-PACS.

Authors:  G Irie; K Miyasaka
Journal:  Comput Med Imaging Graph       Date:  1991 May-Jun       Impact factor: 4.790

2.  Concept of Hokkaido University picture archiving communication system.

Authors:  G Irie
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

3.  Stereotaxic localization of intracranial targets.

Authors:  R L Siddon; N H Barth
Journal:  Int J Radiat Oncol Biol Phys       Date:  1987-08       Impact factor: 7.038

4.  Integrating a personal-computer local-area network with a radiology information system: value as a tool for clinical research.

Authors:  M S Frank; R Berge; E J Stern; J A Johnson
Journal:  AJR Am J Roentgenol       Date:  1994-03       Impact factor: 3.959

5.  Accessing picture archiving and communication system text and image information through personal computers.

Authors:  M R Ramaswamy; A W Wong; J K Lee; H K Huang
Journal:  AJR Am J Roentgenol       Date:  1994-11       Impact factor: 3.959

6.  Precise positioning of intracranial small tumors to the linear accelerator's isocenter, using a stereotactic radiotherapy computed tomography system (SRT-CT).

Authors:  H Shirato; K Suzuki; T Nishioka; T Kamada; K Kagei; T Kitahara; H Morisawa; H Tsujii
Journal:  Radiother Oncol       Date:  1994-08       Impact factor: 6.280

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.