Precise positioning of intracranial small tumors to the linear accelerator's isocenter, using a stereotactic radiotherapy computed tomography system (SRT-CT).

H Shirato1, K Suzuki, T Nishioka, T Kamada, K Kagei, T Kitahara, H Morisawa, H Tsujii.   

Abstract

RT-CT was developed as a simulator using CT scan for radiotherapy. Following three-dimensional treatment planning using CT images, the treatment center and treatment fields are projected to the patients' surface by laser beam on the C arm. The prototype had an accuracy of 3 mm which was equivalent to conventional X-ray simulators but was not adequate for use in stereotactic radiotherapy. A new RT-CT system was developed to have a precise localization capability for stereotactic radiotherapy. Using this stereotactic RT-CT (SRT-CT) after three-dimensional planning, the treatment center is projected to the stereotactic frame automatically. In this study, the values of the x, y and z coordinates of the target center determined by SRT-CT are compared with those determined by the traditional method using CT localizing plates. The discrepancies were within 1.0 mm in 90% and 1.5 mm in 100% of 30 measurements in 16 patients. The disadvantages of SRT-CT may be that the accuracy of localization depends on the quality of calibration of laser beams. The traditional CT localizing method has superiority over SRT-CT because of its solid coordinates but its accuracy is vulnerable to alignment of CT fiducial marker plates. Therefore, the SRT-CT and traditional CT localizing methods would be complementary to each other for precise localization.

Entities:  

Mesh:

Year:  1994        PMID: 7972912     DOI: 10.1016/0167-8140(94)90105-8

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  2 in total

1.  Clinical application of the computer picture archiving and communicating system to stereotactic radiosurgery.

Authors:  T Shiga; H Shirato; Y Kikuchi; T Nishioka; T Kitahara; S Terae; N Nishiyama; X Bo; K Miyasaka
Journal:  J Digit Imaging       Date:  1996-08       Impact factor: 4.056

2.  Selection of external beam radiotherapy approaches for precise and accurate cancer treatment.

Authors:  Hiroki Shirato; Quynh-Thu Le; Keiji Kobashi; Anussara Prayongrat; Seishin Takao; Shinichi Shimizu; Amato Giaccia; Lei Xing; Kikuo Umegaki
Journal:  J Radiat Res       Date:  2018-03-01       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.