Literature DB >> 3301760

Stereotaxic localization of intracranial targets.

R L Siddon, N H Barth.   

Abstract

We report on a useful clinical method for precisely locating intracranial targets. Utilizing the BRW system, the technique is currently used in stereotaxic irradiation of arteriovenous malformations. An intracranial localizer box, with four radio-opaque markers on each face, surrounds the patient's head and is attached to the BRW Head Ring. Two localization films are required. One film includes the target and the eight anterior and posterior markers, whereas the other film includes the target and the eight right and left markers. There are no constraints that the films be orthogonal or parallel to the box faces, only that the target and radio-opaque markers appear on the films. In addition, knowledge of the source-image and source-target distances are not required. Analysis of the projected target and radio-opaque markers gives both the target location and magnification. Simulation with the BRW Phantom Base demonstrates that point targets can be located with respect to the BRW system to within 0.3 mm and magnification determined to within 0.5%.

Entities:  

Mesh:

Year:  1987        PMID: 3301760     DOI: 10.1016/0360-3016(87)90201-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  On the accuracy of isocenter verification with kV imaging in stereotactic radiosurgery.

Authors:  Rolf Wiehle; Hans-Jürgen Koth; Norbert Nanko; Anca-Ligia Grosu; Norbert Hodapp
Journal:  Strahlenther Onkol       Date:  2009-05-15       Impact factor: 3.621

2.  Clinical application of the computer picture archiving and communicating system to stereotactic radiosurgery.

Authors:  T Shiga; H Shirato; Y Kikuchi; T Nishioka; T Kitahara; S Terae; N Nishiyama; X Bo; K Miyasaka
Journal:  J Digit Imaging       Date:  1996-08       Impact factor: 4.056

3.  Effect of fiducial marker defects on stereotactic target localization in the Leksell stereotactic system.

Authors:  Jeong-Hoon Park; Jung Ho Han; Chae-Yong Kim; Chang Wan Oh; Dong Gyu Kim; Tae-Suk Suh; Hyun-Tai Chung
Journal:  Med Biol Eng Comput       Date:  2011-04-10       Impact factor: 2.602

4.  Automatic segmentation of seeds and fluoroscope tracking (FTRAC) fiducial in prostate brachytherapy x-ray images.

Authors:  Nathanael Kuo; Junghoon Lee; Anton Deguet; Danny Song; E Clif Burdette; Jerry Prince
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-23

5.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

6.  Probabilistic mapping of deep brain stimulation effects in essential tremor.

Authors:  Till A Dembek; Michael T Barbe; Mattias Åström; Mauritius Hoevels; Veerle Visser-Vandewalle; Gereon R Fink; Lars Timmermann
Journal:  Neuroimage Clin       Date:  2016-11-17       Impact factor: 4.881

  6 in total