Literature DB >> 8843461

Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification: comparison with conventional radiography.

D B Svanaes1, A Møystad, S Risnes, T A Larheim, H G Gröndahl.   

Abstract

OBJECTIVES: The aim of this study was first to test the newly developed storage phosphor (SP) system Digora for diagnostic accuracy of approximal caries detection with special emphasis on image magnification compared with conventional radiography, and second, to test whether the image surroundings could have an influence on observer performance.
DESIGN: SP plates and Ektaspeed films were exposed simultaneously to 50 extracted premolars/molars, and the SP image files were transported to a different platform for processing. Ten observers rated 95 approximal surfaces for caries with four imaging modalities: (1) SP images at dental film size viewed with black surroundings, (2) magnified (x4) images viewed in the same manner, (3) magnified (x4) images viewed with text and graphics framing, and (4) films viewed on a light box. The observations were validated with microscopy. Diagnostic accuracy was calculated as the area beneath the receiver operating characteristic curve (AZ).
RESULTS: No significant differences were found between SP images and films. Magnified SP images with text and graphics demonstrated significantly higher AZ values than nonmagnified images both for enamel and dentin, and magnified images with black surroundings demonstrated similar results for dentin.
CONCLUSIONS: In this in vitro material the observer performance for approximal caries detection with SP images was comparable to that with Ektaspeed films. The magnified SP images generally showed a significantly higher diagnostic accuracy than the nonmagnified SP images.

Entities:  

Mesh:

Year:  1996        PMID: 8843461     DOI: 10.1016/s1079-2104(96)80385-4

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  7 in total

1.  Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.

Authors:  C J Trapnell; W C Scarfe; J H Cook; A M Silvejra; F J Regennitter; B S Haskell
Journal:  J Digit Imaging       Date:  2000-02       Impact factor: 4.056

2.  Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.

Authors:  A A Pontual; D P de Melo; S M de Almeida; F N Bóscolo; F Haiter Neto
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

3.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

4.  Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies.

Authors:  L Schropp; N S Alyass; A Wenzel; A Stavropoulos
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

5.  The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries.

Authors:  Zahra Dalili Kajan; Reza Tayefeh Davalloo; Mayam Tavangar; Fatemeh Valizade
Journal:  Imaging Sci Dent       Date:  2015-06-19

6.  Comparison of the delay in processing time and protective plastic cases in two phosphor plate systems.

Authors:  Ali Murat Aktan; Mehmet Ertuğrul Ciftçi; Faruk Akgünlü
Journal:  ScientificWorldJournal       Date:  2012-11-07

7.  Diagnostic accuracy of digital and conventional radiography in the detection of non-cavitated approximal dental caries.

Authors:  Farida Abesi; Alireza Mirshekar; Ehsan Moudi; Maryam Seyedmajidi; Sina Haghanifar; Nima Haghighat; Ali Bijani
Journal:  Iran J Radiol       Date:  2012-03-25       Impact factor: 0.212

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.