Literature DB >> 8837279

Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni.

A G Jurik1, L C Jensen, J Hansen.   

Abstract

UNLABELLED: OBJECTIVE DESIGN AND PATIENTS: Conventional frontal tomography of the sternum has to some extent been replaced by spiral computed tomography (CT). The objective of this study was to analyse this change of procedure in terms of dosimetry by measurement of the radiation dose to individual organs using an anthropomorphic Rando Alderson phantom.
RESULTS: The total effective radiation dose in examination of the sternoclavicular joints and the manubrium sterni was found to be lower using spiral CT than conventional tomography, the values being 0.6 and 0.8 mSv, respectively.
CONCLUSION: As spiral CT is diagnostically comparable and in some respects superior to tomography, its use is recommended for studies of the sternum.

Entities:  

Mesh:

Year:  1996        PMID: 8837279     DOI: 10.1007/s002560050116

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  5 in total

1.  The influence of slice thickness on assessment of clavicle ossification in forensic age diagnostics.

Authors:  Matthias Mühler; Ronald Schulz; Sven Schmidt; Andreas Schmeling; Walter Reisinger
Journal:  Int J Legal Med       Date:  2005-07-13       Impact factor: 2.686

2.  Magnetic resonance imaging of the medial extremity of the clavicle in forensic bone age determination: a new four-minute approach.

Authors:  Elke Hillewig; J De Tobel; O Cuche; P Vandemaele; M Piette; K Verstraete
Journal:  Eur Radiol       Date:  2010-10-03       Impact factor: 5.315

3.  Reliability of Schmeling's stages of ossification of medial clavicular epiphyses and its validity to assess 18 years of age in living subjects.

Authors:  R Cameriere; S De Luca; D De Angelis; V Merelli; A Giuliodori; M Cingolani; C Cattaneo; L Ferrante
Journal:  Int J Legal Med       Date:  2012-09-12       Impact factor: 2.686

4.  Radiation exposure during transmission measurements: comparison between CT- and germanium-based techniques with a current PET scanner.

Authors:  Tung-Hsin Wu; Yung-Hui Huang; Jason J S Lee; Shih-Yuan Wang; Su-Cheng Wang; Cheng-Tau Su; Liang-Kung Chen; Tieh-Chi Chu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-08       Impact factor: 9.236

5.  How reliable are the risk estimates for X-ray examinations in forensic age estimations? A safety update.

Authors:  F Ramsthaler; P Proschek; W Betz; M A Verhoff
Journal:  Int J Legal Med       Date:  2009-01-20       Impact factor: 2.686

  5 in total