Corneal stress test for extended wear.

O D Solomon1.   

Abstract

PURPOSE: The relationship between overnight contact lens wear and infectious corneal ulcers has been widely reported. Corneal hypoxia during sleep with contact lenses is believed to be an important predisposing factor for infectious corneal ulcers. We designed a provocative test to identify corneas at risk for significant oxygen deprivation during extended wear.
METHODS: We measured the baseline corneal thickness of 161 eyes (82 patients). Extended wear soft lenses were then fit and pachymetry was repeated after 1 night of extended wear. Patients were instructed to continue extended wear for 6 additional nights.
RESULTS: Seventeen of 161 eyes could not continue extended wear for the full 7 nights. All failures were due to corneal decompensation. There were no failures in the group of 133 eyes with corneal swelling of 5% or less after 1 day of extended wear. All four eyes with swelling greater than 13% failed, while the failure rates for the 24 eyes with swelling between 6-13% was about 50%. The thicker hyperopic lenses produced the majority of failures.
CONCLUSIONS: Measuring corneal swelling after 1 night of extended wear may identify those corneas at risk for significant oxygen deprivation during overnight contact lens wear. Corneal swelling of 5% or less seems to indicate that the cornea can tolerate 7 nights of extended wear (significant to P < 0.001).

Entities:  

Mesh:

Year:  1996        PMID: 8835074

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902


  2 in total

1.  Comparison of central corneal thickness measurements by Pentacam, noncontact specular microscope, and ultrasound pachymetry in normal and post-LASIK eyes.

Authors:  Saleh Al-Ageel; Abdulrahman M Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-10-24

2.  Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy.

Authors:  Haya Matuoq Al Farhan; Wafa'a Majed Al Otaibi; Hanouf Mohammed Al Razqan; Alanoud Abdullah Al Harqan
Journal:  BMC Ophthalmol       Date:  2013-11-25       Impact factor: 2.209