Clinical comparison of the BACTEC 9000 Standard Anaerobic/F and Lytic/F blood culture media.

G E Hollick1, R Edinger, B Martin.   

Abstract

An 8-month prospective, volume controlled, comparison of Standard Anaerobic/F media with a new anaerobic high blood volume lytic medium (Lytic/F) was performed. A total of 2,092 compliant sets, consisting of an aerobic resin bottle or standard aerobic bottle, Standard Anaerobic/F, and Lytic/F bottle were evaluated. A total of 220 (10.6%) positive specimens were detected from the paired anaerobic bottles. These consisted of 194 true positive and 26 false positive bottles. Of 207 total organisms isolated, 122 were considered clinically significant. A comparison of significant organism recovery revealed 79 isolates in both anaerobic bottles, 7 isolates in the standard Anaerobic/F bottle only, and 36 isolates in the Lytic/F bottle only (p < 0.001). The lytic/F bottle detected significantly more Enterobacteriaceae (p < 0.005) and Streptococci (p < 0.05). There were 24 false positive Standard Anaerobic/F bottles and 2 false positive Lytic/F bottles (p < 0.001). When both bottles were positive the Standard Anaerobic/F bottle was positive 12 hours earlier in 1 instance whereas the Lytic/F bottle was positive 12 hours earlier in 8 instances. The mean time for detection in the Standard Anaerobic/F bottle was 18.2 hours versus 13.2 hours for the Lytic/F bottle. The new Lytic/F anaerobic blood culture media was found to be superior to Standard Anaerobic/F media for both total organism recovery and time to organism detection.

Mesh:

Substances:

Year:  1996        PMID: 8831032     DOI: 10.1016/0732-8893(96)00060-0

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  4 in total

1.  Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

Authors:  M L Wilson; S Mirrett; F T Meredith; M P Weinstein; V Scotto; L B Reller
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

2.  Performance of a new combination of blood culture vials in sepsis detection: a 2-year retrospective comparison.

Authors:  Paolo Bottino; Fabio Rapallo; Elisa Gamalero; Andrea Rocchetti
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-05-08       Impact factor: 3.267

3.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

4.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.