The effect of speed, pressure, and time on bone temperature during the drilling of implant sites.

D L Brisman.   

Abstract

It is critical for the success of endosseous root-form implants that minimal heat is generated in the bone during the drilling of the implant sites. One aspect that has received little emphasis in the literature is the effect of the load placed on the drill during preparation of osteotomies. Temperatures and time were measured while drilling bovine cortical bone at speeds of 1,800 and 2,400 rpm and loads of 1.2 and 2.4 kg. Drilling at a low speed of 1,800 rpm and at a minimal load of 1.2 kg produced the same heat as when the drill speed was increased to 2,400 rpm and the load was increased to 2.4 kg. Independently increasing either the speed or the load caused an increase in temperature in bone. However, increasing both the speed and the load together allowed for more efficient cutting with no significant increase in temperature.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8820120

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  33 in total

1.  [Reaming debris: a source of vital cells! First results of human specimens].

Authors:  K Trinkaus; S Wenisch; C Siemers; D Hose; R Schnettler
Journal:  Unfallchirurg       Date:  2005-08       Impact factor: 1.000

2.  Study of temperature variation in cortical bone during osteotomies with trephine drills.

Authors:  Sergio Alexandre Gehrke; Marcelo Khoury Pazetto; Sérgio de Oliveira; Stefano Corbella; Silvio Taschieri; Fábio E C Mardegan
Journal:  Clin Oral Investig       Date:  2014-01-08       Impact factor: 3.573

Review 3.  Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-02-18

4.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

5.  Optimization of multiple quality characteristics in bone drilling using grey relational analysis.

Authors:  Rupesh Kumar Pandey; Sudhansu Sekhar Panda
Journal:  J Orthop       Date:  2014-07-17

6.  Identification of possible factors influencing temperatures elevation during implant site preparation with piezoelectric technique.

Authors:  Luca Lamazza; Domenica Laurito; Marco Lollobrigida; Orlando Brugnoletti; Girolamo Garreffa; Alberto De Biase
Journal:  Ann Stomatol (Roma)       Date:  2015-02-09

7.  Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

Authors:  R A Delgado-Ruiz; E Velasco Ortega; G E Romanos; S Gerhke; I Newen; J L Calvo-Guirado
Journal:  Clin Oral Investig       Date:  2017-04-22       Impact factor: 3.573

8.  Temperature Rise in Kirschner Wires Inserted Using Two Drilling Methods: Forward and Oscillation.

Authors:  Scott Richard Anderson; Serkan Inceoglu; Montri D Wongworawat
Journal:  Hand (N Y)       Date:  2017-05-16

Review 9.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

10.  Hammering K-wires is superior to drilling with irrigation.

Authors:  Bas B G M Franssen; Arnold H Schuurman; Pascal C R Brouha; Moshe Kon
Journal:  Hand (N Y)       Date:  2008-12-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.