Literature DB >> 8809627

The nonlinear transition period of broadband ultrasound attenuation as bone density varies.

L Serpe1, J Y Rho.   

Abstract

The purpose of this study was to determine whether a transition period occurs between cortical and cancellous bone in the relationship between ultrasound parameters [broadband ultrasound attenuation (BUA) and ultrasonic velocity] and density. Twenty-two cancellous bone discs wee obtained from proximal bovine tibiae. Also included were three samples of human vertebral cancellous bone from an elderly female and four samples of bovine cortical bone. Ultrasonic velocity did not show any transition period as density varied from cancellous to cortical bone. Ultrasonic velocity exhibited a definite linear dependence on density over the entire range examined. However, BUA has shown a transition period as density varied. Although BUA increased linearly with density for a low density cancellous bone tested (below 0.64 g cm-3), the dependence of BUA on density is nonlinear with a downwardly inflected parabola shape when covering a wide density range (0.130-0.913 g cm-3) of cancellous bone. When one includes cortical bone, the parabola tends to level off in a slow exponential decay. This nonlinear dependence may help to understand the characteristics of BUA measurement.

Entities:  

Mesh:

Year:  1996        PMID: 8809627     DOI: 10.1016/0021-9290(95)00146-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Fundamental precision limitations for measurements of frequency dependence of backscatter: applications in tissue-mimicking phantoms and trabecular bone.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  2001-12       Impact factor: 1.840

2.  The dependence of ultrasonic backscatter on trabecular thickness in human calcaneus: theoretical and experimental results.

Authors:  Keith A Wear; Andres Laib
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-08       Impact factor: 2.725

3.  Ultrasound simulation in the distal radius using clinical high-resolution peripheral-CT images.

Authors:  Vincent Le Floch; Donald J McMahon; Gangming Luo; Adi Cohen; Jonathan J Kaufman; Elizabeth Shane; Robert S Siffert
Journal:  Ultrasound Med Biol       Date:  2008-03-14       Impact factor: 2.998

4.  Mechanisms for attenuation in cancellous-bone-mimicking phantoms.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-11       Impact factor: 2.725

Review 5.  Ultrasonic scattering from cancellous bone: a review.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

6.  The influence of porosity and pore size on the ultrasonic properties of bone investigated using a phantom material.

Authors:  R Strelitzki; J A Evans; A J Clarke
Journal:  Osteoporos Int       Date:  1997       Impact factor: 4.507

7.  Effects of phase cancellation and receiver aperture size on broadband ultrasonic attenuation for trabecular bone in vitro.

Authors:  Jiqi Cheng; Frederick Serra-Hsu; Yuan Tian; Wei Lin; Yi-Xian Qin
Journal:  Ultrasound Med Biol       Date:  2011-10-26       Impact factor: 2.998

Review 8.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

9.  Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound.

Authors:  Yi-Xian Qin; Wei Lin; Erik Mittra; Yi Xia; Jiqi Cheng; Stefan Judex; Clint Rubin; Ralph Müller
Journal:  Acta Astronaut       Date:  2013-11       Impact factor: 2.413

10.  Ultrasonic attenuation in human calcaneus from 0.2 to 1.7 MHz.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-03       Impact factor: 3.267

View more