Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex.

E M Schmidt1, M J Bak, F T Hambrecht, C V Kufta, D K O'Rourke, P Vallabhanath.   

Abstract

The feasibility of producing a visual prosthesis for the blind using intracortical microstimulation (ICMS) of the visual cortex was studied in a 42-year-old woman who had been totally blind for 22 years secondary to glaucoma. Thirty-eight microelectrodes were implanted in the right visual cortex, near the occipital pole, for a period of 4 months. Percepts reported as small spots of light, called phosphenes, were produced with 34 of the 38 implanted microelectrodes. Threshold currents for phosphene generation with trains of biphasic pulses were as low as 1.9 microA, and most of the microelectrodes had thresholds below 25 microA. Phosphene brightness could be modified with stimulus amplitude, frequency and pulse duration. Repeated stimulation over a period of minutes produced a gradual decrease in phosphene brightness. Phosphenes did not flicker. The apparent size of phosphenes ranged from a "pin-point' to a "nickel' (20 mm diameter coin) held at arm's length. Phosphene size usually decreased as stimulation current was increased but increased slightly as the train length (TL) was increased. At levels of stimulation near threshold, the phosphenes were often reported to have colours. As the stimulation level was increased, the phosphenes generally became white, greyish or yellowish. Individual phosphenes appeared at different distances from the subject. When two phosphenes were simultaneously generated, the apparent distances of the individual phosphenes sometimes changed to make them appear to be at about the same distance. When three or more phosphenes were simultaneously generated, they became coplanar. Except for rare occasions, phosphenes extinguished rapidly at the termination of the stimulation train. When stimulation TLs were increased beyond 1 s, phosphenes usually disappeared before the end of the train. The duration of phosphene perception could be increased by interrupting a long stimulation train with brief pauses in stimulation. Intracortical microelectrodes spaced 500 microns apart generated separate phosphenes, but microelectrodes spaced 250 microns typically did not. This two-point resolution was about five times closer than has typically been achieved with surface stimulation. With some individual microelectrodes, a second closely spaced phosphene was sometimes produced by increasing the stimulation current. Phosphenes moved with eye movements. When up to six phosphenes were simultaneously elicited, they all moved with the same relative orientation during eye movements. All phosphenes were located in the left hemi-field with the majority above the horizontal meridian. There was a clustering of most of the phosphenes within a relatively small area of visual space. The potentially greater microelectrode density and lower power requirements of ICMS compared with surface stimulation appears encouraging for a visual prosthesis. However, further studies with blind subjects are required to optimize stimulation parameters and test complex image recognition before the feasibility of a visual prosthesis based on ICMS can be established.

Entities:  

Mesh:

Year:  1996        PMID: 8800945     DOI: 10.1093/brain/119.2.507

Source DB:  PubMed          Journal:  Brain        ISSN: 0006-8950            Impact factor:   13.501


  126 in total

1.  In vivo microstimulation with cathodic and anodic asymmetric waveforms modulates spatiotemporal calcium dynamics in cortical neuropil and pyramidal neurons of male mice.

Authors:  Kevin C Stieger; James R Eles; Kip A Ludwig; Takashi D Y Kozai
Journal:  J Neurosci Res       Date:  2020-06-26       Impact factor: 4.164

2.  Towards the cortical representation of form and motion stimuli generated by a retina implant.

Authors:  Thomas Schanze; Nina Greve; Lutz Hesse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-29       Impact factor: 3.117

3.  Frequency and amplitude modulation have different effects on the percepts elicited by retinal stimulation.

Authors:  Devyani Nanduri; Ione Fine; Alan Horsager; Geoffrey M Boynton; Mark S Humayun; Robert J Greenberg; James D Weiland
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-20       Impact factor: 4.799

4.  New methods devised specify the size and color of the spots monkeys see when striate cortex (area V1) is electrically stimulated.

Authors:  Peter H Schiller; Warren M Slocum; Michelle C Kwak; Geoffrey L Kendall; Edward J Tehovnik
Journal:  Proc Natl Acad Sci U S A       Date:  2011-10-10       Impact factor: 11.205

Review 5.  Insights into cortical mechanisms of behavior from microstimulation experiments.

Authors:  Mark H Histed; Amy M Ni; John H R Maunsell
Journal:  Prog Neurobiol       Date:  2012-01-28       Impact factor: 11.685

6.  Ethical considerations for volunteer recruitment of visual prosthesis trials.

Authors:  Yu Xia; Qiushi Ren
Journal:  Sci Eng Ethics       Date:  2012-06-23       Impact factor: 3.525

Review 7.  Neuromodulation for brain disorders: challenges and opportunities.

Authors:  Matthew D Johnson; Hubert H Lim; Theoden I Netoff; Allison T Connolly; Nessa Johnson; Abhrajeet Roy; Abbey Holt; Kelvin O Lim; James R Carey; Jerrold L Vitek; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2013-02-01       Impact factor: 4.538

8.  Subretinal implantation and testing of polyimide film electrodes in cats.

Authors:  Helmut G Sachs; Thomas Schanze; Marcus Wilms; Andreas Rentzos; Ursula Brunner; Florian Gekeler; Lutz Hesse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-01       Impact factor: 3.117

Review 9.  Electrical stimulation of cranial nerves in cognition and disease.

Authors:  Devin Adair; Dennis Truong; Zeinab Esmaeilpour; Nigel Gebodh; Helen Borges; Libby Ho; J Douglas Bremner; Bashar W Badran; Vitaly Napadow; Vincent P Clark; Marom Bikson
Journal:  Brain Stimul       Date:  2020-02-23       Impact factor: 8.955

10.  Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.

Authors:  Christi L Kolarcik; Kasey Catt; Erika Rost; Ingrid N Albrecht; Dennis Bourbeau; Zhanhong Du; Takashi D Y Kozai; Xiliang Luo; Douglas J Weber; X Tracy Cui
Journal:  J Neural Eng       Date:  2014-12-08       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.