Literature DB >> 8795367

On the precision and reliability of IOP measurements.

J M Gilchrist1.   

Abstract

Mesh:

Year:  1996        PMID: 8795367      PMCID: PMC505549          DOI: 10.1136/bjo.80.7.586

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


× No keyword cloud information.
  21 in total

1.  Measurement of intraocular pressure: a study of its reproducibility.

Authors:  C D Phelps; G K Phelps
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-01-16

2.  Repeated applanation tonometry.

Authors:  R A MOSES
Journal:  Ophthalmologica       Date:  1961       Impact factor: 3.250

3.  A new handheld air impulse tonometer.

Authors:  J H Fisher; P G Watson; G Spaeth
Journal:  Eye (Lond)       Date:  1988       Impact factor: 3.775

4.  Comparison of the Pulsair noncontact tonometer and the Goldmann applanation tonometer.

Authors:  H Climenhaga; H Plucinska
Journal:  Can J Ophthalmol       Date:  1989-02       Impact factor: 1.882

5.  Clinical evaluation of the Non-Contact Tonometer Mark II.

Authors:  B C Chauhan; D B Henson
Journal:  Am J Optom Physiol Opt       Date:  1988-09

6.  Validity and reliability of visual acuity measurements.

Authors:  J E Lovie-Kitchin
Journal:  Ophthalmic Physiol Opt       Date:  1988       Impact factor: 3.117

7.  Effects of repeated tonometry: genuine and sham measurements.

Authors:  K Wilke
Journal:  Acta Ophthalmol (Copenh)       Date:  1972

8.  On repeated tonometry.

Authors:  C E Krakau; K Wilke
Journal:  Acta Ophthalmol (Copenh)       Date:  1971

9.  A study of the errors of applanation tonometry and tonography on two groups of normal people.

Authors:  V Berry; S M Drance; R L Wiggins; M Schulzer
Journal:  Can J Ophthalmol       Date:  1966-07       Impact factor: 1.882

10.  The noncontact tonometer. Clinical evaluation on normal and diseased eyes.

Authors:  P N Sorensen
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-09
View more
  2 in total

1.  Does rebound tonometry probe misalignment modify intraocular pressure measurements in human eyes?

Authors:  Ian G Beasley; Deborah S Laughton; Benjamin J Coldrick; Thomas E Drew; Marium Sallah; Leon N Davies
Journal:  J Ophthalmol       Date:  2013-08-29       Impact factor: 1.909

2.  Genome-wide association study of corneal biomechanical properties identifies over 200 loci providing insight into the genetic etiology of ocular diseases.

Authors:  Mark J Simcoe; Anthony P Khawaja; Pirro G Hysi; Christopher J Hammond
Journal:  Hum Mol Genet       Date:  2020-11-04       Impact factor: 6.150

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.