Literature DB >> 1242275

The noncontact tonometer. Clinical evaluation on normal and diseased eyes.

P N Sorensen.   

Abstract

The measurement of intraocular pressure with a noncontact tonometer was correlated to a Goldmann tonometer in 20 normal persons, 20 glaucomatous patients, and 8 patients suffering from corneal diseases. In normal persons the error in measurement for the noncontact tonometer was related to their skill in fixation, and in eye patients to height of pressure and corneal state. Acceptable correlation was found between noncontact tonometry and Goldmann applanation tonometry when the cornea was normal and the pressure below 35 mmHg (Goldmann), otherwise noncontact tonometry was only a guide, and in the presence of corneal disease, unreliable. Good fixation reduced the method error. The standard deviation was 1.09 mmHg at poor fixation and 0.60 mmHg at good fixation. Repeated measurements on the same eye with noncontact tonometry did not alter the intraocular tension.

Entities:  

Mesh:

Year:  1975        PMID: 1242275     DOI: 10.1111/j.1755-3768.1975.tb01771.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  6 in total

1.  Evaluation of Keeler Pulsair non-contact tonometry: reliability and reproducibility.

Authors:  L Bonomi; S Baravelli; C Cobbe; L Tomazzoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

2.  On the precision and reliability of IOP measurements.

Authors:  J M Gilchrist
Journal:  Br J Ophthalmol       Date:  1996-07       Impact factor: 4.638

3.  Decrease in intraocular pressure following orthokeratology measured with a noncontact tonometer.

Authors:  Yasuhito Ishida; Ryoji Yanai; Takeshi Sagara; Teruo Nishida; Hiroshi Toshida; Akira Murakami
Journal:  Jpn J Ophthalmol       Date:  2011-05-15       Impact factor: 2.447

4.  Performance of the PT100 noncontact tonometer in healthy eyes.

Authors:  Turki M AlMubrad
Journal:  Clin Ophthalmol       Date:  2011-05-19

5.  Intraocular Pressure Based on Dynamic Bidirectional Applanation and Air-puff Tonometry: A Comparative Study.

Authors:  Ayse E Bahadir Kilavuzoglu; Cemile B Cosar; Ali Rc Celebi; Ugur E Al Parmak
Journal:  J Curr Glaucoma Pract       Date:  2019 May-Aug

6.  Intraocular pressure according to different types of tonometry (non-contact and Goldmann applanation) in patients with different degrees of bilateral tearing.

Authors:  Bo Ram Seol; Tae Gu Kang; Bonhyeok Gu
Journal:  PLoS One       Date:  2019-09-16       Impact factor: 3.240