Literature DB >> 8795027

Pulsed magnetization transfer contrast in gradient echo imaging: a two-pool analytic description of signal response.

G B Pike1.   

Abstract

Magnetization transfer (MT) imaging with a rapid gradient-echo sequence and pulsed saturation provides an efficient means of acquiring high resolution three-dimensional data in vivo. This paper presents a derivation of the theoretical steady-state signal equation for this sequence based on the two-site coupled Bloch equations. Numerical simulations are used to validate the derived expression and experiments are performed on an agar gel model and normal brain. Experimental agar data indicate that direct saturation of the liquid component can be a major source of signal attenuation whereas MT normally dominates in brain tissue. The signal equation presented here establishes the necessary theory for sequence design and optimization and provides insight into model parameters and experimental results.

Mesh:

Substances:

Year:  1996        PMID: 8795027     DOI: 10.1002/mrm.1910360117

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Dynamics of paramagnetic agents by off-resonance rotating frame technique in the presence of magnetization transfer effect.

Authors:  Huiming Zhang; Yang Xie
Journal:  J Magn Reson       Date:  2006-11-22       Impact factor: 2.229

2.  MT effects and T1 quantification in single-slice spoiled gradient echo imaging.

Authors:  Xiawei Ou; Daniel Frank Gochberg
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

Review 3.  Magnetization transfer imaging of multiple sclerosis.

Authors:  G B Pike
Journal:  Ital J Neurol Sci       Date:  1997-12

4.  Three-dimensional inhomogeneous magnetization transfer with rapid gradient-echo (3D ihMTRAGE) imaging.

Authors:  Gopal Varma; Fanny Munsch; Brian Burns; Guillaume Duhamel; Olivier M Girard; Arnaud Guidon; R Marc Lebel; David C Alsop
Journal:  Magn Reson Med       Date:  2020-06-30       Impact factor: 4.668

Review 5.  Studying neuroanatomy using MRI.

Authors:  Jason P Lerch; André J W van der Kouwe; Armin Raznahan; Tomáš Paus; Heidi Johansen-Berg; Karla L Miller; Stephen M Smith; Bruce Fischl; Stamatios N Sotiropoulos
Journal:  Nat Neurosci       Date:  2017-02-23       Impact factor: 24.884

Review 6.  CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Authors:  Linda Knutsson; Jiadi Xu; André Ahlgren; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

7.  Four in vivo g-ratio-weighted imaging methods: Comparability and repeatability at the group level.

Authors:  Isabel Ellerbrock; Siawoosh Mohammadi
Journal:  Hum Brain Mapp       Date:  2017-11-01       Impact factor: 5.038

Review 8.  Advanced MRI strategies for assessing spinal cord injury.

Authors:  Seth A Smith; James J Pekar; Peter C M van Zijl
Journal:  Handb Clin Neurol       Date:  2012

Review 9.  Magnetization Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum.

Authors:  Peter C M van Zijl; Wilfred W Lam; Jiadi Xu; Linda Knutsson; Greg J Stanisz
Journal:  Neuroimage       Date:  2017-04-21       Impact factor: 6.556

10.  Magnetization transfer characteristics in atherosclerotic plaque components assessed by adapted binomial preparation pulses.

Authors:  M Pachot-Clouard; F Vaufrey; L Darrasse; J F Toussainti
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

View more