Literature DB >> 8794602

Umbilical coiling index: is it a marker for the foetus at risk?

T Ercal1, S Lacin, S Altunyurt, U Saygili, O Cinar, A Mumcu.   

Abstract

The aim of this study was to determine the relationship between the number of coils in the umbilical cord and perinatal outcome. The umbilical cords and delivery records of 147 liveborn neonates were prospectively studied. The umbilical coiling index (UCI) of each cord was calculated by dividing the total number of complete umbilical vascular coils by the umbilical cord length. Subjects with UCIs below the 10th percentile, above the 90th percentile, and between the 10th and 90th percentiles were defined as hypocoiled, hypercoiled, and normocoiled, respectively. Several different parameters were used to measure neonatal outcome. The mean UCI was 0.20 +/- 10 (SD). No relationship was noted between UCI and maternal age, gravidity, parity, oligohydramnios, or birth weight. When we compared the hypocoiled group (n = 30) with the normocoiled group (n = 87), we detected a statistically significantly higher incidence of meconium staining, interventional delivery, apgar scores, fetal blood pH and intrapartum fetal heart rate disturbances. As a result, we concluded that the UCI has a strong relationship with perinatal outcome and may be used antenatally as a marker for identifying the fetus at risk.

Mesh:

Year:  1996        PMID: 8794602

Source DB:  PubMed          Journal:  Br J Clin Pract        ISSN: 0007-0947


  6 in total

1.  Umbilical cord coiling index and perinatal outcome.

Authors:  Nivedita S Patil; Sunanda R Kulkarni; Renu Lohitashwa
Journal:  J Clin Diagn Res       Date:  2013-08-01

Review 2.  Umbilical cord coiling: clinical outcomes in an unselected population and systematic review.

Authors:  F A Jessop; C C Lees; S Pathak; C E Hook; N J Sebire
Journal:  Virchows Arch       Date:  2013-11-21       Impact factor: 4.064

3.  A case report of umbilical ring constriction with application of amnioinfusion.

Authors:  Mayumi Tokunaka; Junichi Hasegawa; Masamitsu Nakamura; Shoko Hamada; Ryu Matsuoka; Kiyotake Ichizuka; Akihiko Sekizawa; Takashi Okai
Journal:  J Med Ultrason (2001)       Date:  2013-05-11       Impact factor: 1.314

4.  The sonographic umbilical cord coiling in late second trimester of gestation and perinatal outcomes.

Authors:  Yun Sung Jo; Dong Kue Jang; Guisera Lee
Journal:  Int J Med Sci       Date:  2011-10-07       Impact factor: 3.738

5.  Umbilical coiling index as a marker of perinatal outcome: an analytical study.

Authors:  T Chitra; Y S Sushanth; S Raghavan
Journal:  Obstet Gynecol Int       Date:  2012-02-14

6.  Umbilical cord coiling: case report and review of literature.

Authors:  Rajendra Kumar Diwakar; Meena M Naik; Monika M Jindal
Journal:  BJR Case Rep       Date:  2016-07-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.