Literature DB >> 8792736

Megaprostheses after resection of distal femoral tumors. A rotating hinge design in 30 patients followed for 2-7 years.

P F Choong1, F H Sim, D J Pritchard, M G Rock, E Y Chao.   

Abstract

Between 1981-1993, we inserted 32 Kinematic Rotating-Hinge Knee tumor prostheses in 30 patients, of which 2 concerned revisions of the same type of prosthesis. The diagnoses were 21 osteosarcomas, 2 chondrosarcomas, 2 Ewing's sarcomas, 2 metastatic breast carcinomas, 1 multiple myeloma, 1 giant cell tumor and 1 Gorham's disease. The median age was 25 (12-60) years and the median follow-up for survivors was 3.5 (2-6.6) years. There were 7 metastases and 1 local recurrence. 20 knees had excellent (MSTS) scores for motion (median flexion 120 degrees), 8 had good (84 degrees) and 4 had fair (45 degrees). The overall function was excellent in 6 cases, good in 14, fair in 9 and poor in 3. The radiographic assessment (ISOLS) gave "excellent" or "good" scores in 27 knees for bone remodelling, 31 for the interface, 28 for the anchorage, 31 for the implant body and 30 for the articulation. Extracortical bone bridging greater than 25% was observed in 18 of 27 prostheses.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8792736     DOI: 10.3109/17453679609002328

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  18 in total

1.  Revision of broken knee megaprostheses: new solution to old problems.

Authors:  Manish Agarwal; Ashish Gulia; B Ravi; Rupesh Ghyar; Ajay Puri
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

Review 2.  Megaprostheses for the treatment of malignant bone tumours of the lower limbs.

Authors:  Christian Heisel; Stefan Kinkel; Ludger Bernd; Volker Ewerbeck
Journal:  Int Orthop       Date:  2006-09-12       Impact factor: 3.075

3.  Causes and Frequencies of Reoperations After Endoprosthetic Reconstructions for Extremity Tumor Surgery: A Systematic Review.

Authors:  Patrick Thornley; Matias Vicente; Austin MacDonald; Nathan Evaniew; Michelle Ghert; Roberto Velez
Journal:  Clin Orthop Relat Res       Date:  2019-04       Impact factor: 4.176

Review 4.  [Revision of tumour endoprostheses around the knee joint. Review and own results].

Authors:  R Windhager; A Leithner; M Hochegger
Journal:  Orthopade       Date:  2006-02       Impact factor: 1.087

5.  Late complications and survival of endoprosthetic reconstruction after resection of bone tumors.

Authors:  Ahmad Shehadeh; Jenna Noveau; Martin Malawer; Robert Henshaw
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

6.  Distal femur reconstruction with modular tumour prostheses: a single Institution analysis of implant survival comparing fixed versus rotating hinge knee prostheses.

Authors:  Elisa Pala; Giulia Trovarelli; Andrea Angelini; Pietro Ruggieri
Journal:  Int Orthop       Date:  2016-06-04       Impact factor: 3.075

Review 7.  Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.

Authors:  Joerg Friesenbichler; Ran Schwarzkopf; Patrick Sadoghi; Scott E Marwin; Mathias Glehr; Werner Maurer-Ertl; Andreas Leithner
Journal:  Int Orthop       Date:  2011-12-28       Impact factor: 3.075

8.  Mid-term survival following primary hinged total knee replacement is good irrespective of the indication for surgery.

Authors:  Paul Baker; Rebecca Critchley; Andrew Gray; Simon Jameson; Paul Gregg; Andrew Port; David Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

9.  Distal femoral replacement in nontumor cases with severe bone loss and instability.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2008-06-04       Impact factor: 4.176

10.  Cemented distal femoral endoprostheses for musculoskeletal tumor: improved survival of modular versus custom implants.

Authors:  Adam J Schwartz; J Michael Kabo; Fritz C Eilber; Frederick R Eilber; Jeffrey J Eckardt
Journal:  Clin Orthop Relat Res       Date:  2009-12-22       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.