Literature DB >> 10584328

Sheathless preconcentration-capillary zone electrophoresis-mass spectrometry applied to peptide analysis.

M B Barroso1, A P de Jong.   

Abstract

A reliable capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry system has been developed for the sensitive analysis and sequencing of peptides. The system comprises (1) a zero dead volume on-line sample preconcentration interface allowing over 100-fold increase in sample volume introduction and (2) a zero-dead volume, durable electrospray emitter yielding stable, low background electrospray signals, both proving not to compromize the electrophoretic performance. Sub-fmol sensitivities were obtained in applications to complex peptide samples derived from tryptic digestion of proteins and naturally processed major histocompatibility complex class I associated peptides.

Mesh:

Substances:

Year:  1999        PMID: 10584328     DOI: 10.1016/s1044-0305(99)00101-4

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  14 in total

1.  Long-lived metallized tips for nanoliter electrospray mass spectrometry.

Authors:  G A Valaskovic; F W McLafferty
Journal:  J Am Soc Mass Spectrom       Date:  1996-12       Impact factor: 3.109

Review 2.  Structure of peptides associated with class I and class II MHC molecules.

Authors:  V H Engelhard
Journal:  Annu Rev Immunol       Date:  1994       Impact factor: 28.527

3.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

4.  The use of solid phase concentrators for on-line preconcentration of metallothionein prior to isoform separation by capillary zone electrophoresis.

Authors:  J H Beattie; R Self; M P Richards
Journal:  Electrophoresis       Date:  1995-03       Impact factor: 3.535

5.  Concentration and separation of hypoglycemic drugs using solid-phase extraction-capillary electrophoresis.

Authors:  M A Strausbauch; S J Xu; J E Ferguson; M E Nunez; D Machacek; G M Lawson; P J Wettstein; J P Landers
Journal:  J Chromatogr A       Date:  1995-11-24       Impact factor: 4.759

6.  Durable gold-coated fused silica capillaries for use in electrospray mass spectrometry.

Authors:  M S Kriger; K D Cook; R S Ramsey
Journal:  Anal Chem       Date:  1995-01-15       Impact factor: 6.986

7.  Controversies in the clinical chemistry laboratory.

Authors: 
Journal:  Anal Chem       Date:  1993-06-01       Impact factor: 6.986

8.  Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 mu m I.D. capillaries: analyses of tryptic digests of cytochrome c.

Authors:  J H Wahl; D C Gale; R D Smith
Journal:  J Chromatogr A       Date:  1994-01-21       Impact factor: 4.759

9.  Mechanism of peptide separations by solid phase extraction capillary electrophoresis at low pH.

Authors:  M A Strausbauch; J P Landers; P J Wettstein
Journal:  Anal Chem       Date:  1996-01-15       Impact factor: 6.986

10.  Identification of a graft versus host disease-associated human minor histocompatibility antigen.

Authors:  J M den Haan; N E Sherman; E Blokland; E Huczko; F Koning; J W Drijfhout; J Skipper; J Shabanowitz; D F Hunt; V H Engelhard
Journal:  Science       Date:  1995-06-09       Impact factor: 47.728

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.