Literature DB >> 8753659

Pediatric hepatic CT: an injection protocol.

K J Roche1, N B Genieser, M M Ambrosino.   

Abstract

OBJECTIVE: To determine an injection protocol for pediatric hepatic CT and to investigate the use of power injection.
MATERIALS AND METHODS: Eighty-seven studies were prospectively performed using ioversol (320 mg iodine per cc) at 2 cc/kg. Three techniques were used: helical (1 s/slice); dynamic, non-breath-hold (5.5 s/slice); dynamic, breath-hold (10 s/slice) scans. The liver-scan time for each study was determined. Scan initiation ranged from 25 to 80 s. An injection duration (50-100 seconds) was selected. From the contrast volume (2 cc/kg x kg body wt) and injection duration, the injection rate (cc/s) was calculated for each patient. Each study was grouped by injection rate corrected for body weight (cc/kg/min) into: 1.2-1.5, 1.51-2.0, and 2.01-2.4. The aortic/liver attenuation curves were plotted for each group.
RESULTS: Liver-scan time for helical studies was a mean of 26 s, for dynamic, non-breath-hold studies 75 s, dynamic breath-hold scans were 154 s. Injection rates of 1.2-1.5 cc/kg/min produced a scanning interval of 165 s. Injection rates of 1.51-2.0 cc/kg/min produced a scanning interval of 120 s. Injection rates of 2.01-2.4 cc/kg/min produced a scanning interval of 90 s. There was no increase in hepatic attenuation for the injection rates 2.01-2.4 cc/kg/min compared with 1.51-2.0 cc/kg/min. There was one complication related to injection through a central line.
CONCLUSIONS: An injection protocol was determined for helical studies with injection rates of 1.7-2.0 cc/kg/min with initiation at 60 s; for dynamic, non-breath-hold studies with injection rates of 1.5-1.7 cc/kg/min with initiation at 50 s; and for dynamic breath-hold studies with injection rates of 1.2-1.5 cc/kg/min with initiation at 45 s. Power injection was used safely in our population.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8753659     DOI: 10.1007/bf01372229

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  12 in total

1.  Right window for dynamic hepatic CT.

Authors:  I H Cox; W D Foley; R G Hoffmann
Journal:  Radiology       Date:  1991-10       Impact factor: 11.105

2.  Dynamic hepatic CT: how many years will it take 'til we learn?

Authors:  M M Walkey
Journal:  Radiology       Date:  1991-10       Impact factor: 11.105

3.  Dynamic hepatic CT.

Authors:  W D Foley
Journal:  Radiology       Date:  1989-03       Impact factor: 11.105

Review 4.  Hepatic CT: state of the art.

Authors:  P C Freeny
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

5.  The use of a flow rate injector for contrast-enhanced computed tomography.

Authors:  S McCarthy; A A Moss
Journal:  Radiology       Date:  1984-06       Impact factor: 11.105

6.  Contrast enhancement technique for dynamic hepatic computed tomographic scanning.

Authors:  W D Foley; L L Berland; T L Lawson; D F Smith; M K Thorsen
Journal:  Radiology       Date:  1983-06       Impact factor: 11.105

7.  Bolus geometry and dynamics after intravenous contrast medium injection.

Authors:  C D Claussen; D Banzer; C Pfretzschner; W A Kalender; W Schörner
Journal:  Radiology       Date:  1984-11       Impact factor: 11.105

8.  Contrast-enhanced CT of the liver and spleen: comparison of ionic and nonionic contrast agents.

Authors:  R C Nelson; J L Chezmar; J E Peterson; M E Bernardino
Journal:  AJR Am J Roentgenol       Date:  1989-11       Impact factor: 3.959

9.  Comparison of contrast media injection rates and volumes for hepatic dynamic incremented computed tomography.

Authors:  L L Berland; J Y Lee
Journal:  Invest Radiol       Date:  1988-12       Impact factor: 6.016

10.  Hepatic CT enhancement: comparison of ionic and nonionic contrast agents in the same patients.

Authors:  T P Chambers; R L Baron; R M Lush; G D Dodd; W J Miller
Journal:  Radiology       Date:  1994-03       Impact factor: 11.105

View more
  2 in total

Review 1.  Pediatric liver tumors--a pictorial review.

Authors:  Priyanka Jha; Soni C Chawla; Sidhartha Tavri; Chirag Patel; Charles Gooding; Heike Daldrup-Link
Journal:  Eur Radiol       Date:  2008-08-06       Impact factor: 5.315

Review 2.  Systematic review of the safety and efficacy of contrast injection via venous catheters for contrast-enhanced computed tomography.

Authors:  S B Buijs; M W Barentsz; M L J Smits; J W C Gratama; P E Spronk
Journal:  Eur J Radiol Open       Date:  2017-09-29
  2 in total