Radiofrequency shielding of surface coils at 4.0 T.

K C Ong1, H Wen, A S Chesnick, S Duewell, F A Jaffer, R S Balaban.   

Abstract

Because radiation loss associated with a radiofrequency (RF) coil increases as roughly the fourth power of the frequency, this loss mechanism may become important in high-field studies above 2.0 T. In this study, the contribution of radiation losses at 4.0 T were determined in a rectangular surface coil using an RF shield to modify the radiation losses. The effect of this shield was determined on coil Q, B1 distribution, and signal to noise as a function of distance between the coil and the shield. Phantoms and human tissue were evaluated to characterize the loss mechanisms. The results demonstrate a large radiation loss in the unshielded surface coil. However, the radiation losses in vivo were not dominant owing to a large inductive loss occurring from dielectric currents in the body at 170 MHz.

Entities:  

Mesh:

Year:  1995        PMID: 8748501     DOI: 10.1002/jmri.1880050626

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Effects of coplanar shielding for high field MRI.

Authors:  Joseph V Rispoli; Matthew D Wilcox; Samantha By; Steven M Wright; Mary P McDougall
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

2.  Common-mode differential-mode (CMDM) method for double-nuclear MR signal excitation and reception at ultrahigh fields.

Authors:  Yong Pang; Xiaoliang Zhang; Zhentian Xie; Chunsheng Wang; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2011-06-20       Impact factor: 10.048

Review 3.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

4.  Evaluation of Common RF Coil Setups for MR Imaging at Ultrahigh Magnetic Field: A Numerical Study.

Authors:  Jonathan Lu; Yong Pang; Chunsheng Wang; Bing Wu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Int Symp Appl Sci Biomed Commun Technol       Date:  2011

5.  Effect of radiofrequency shield diameter on signal-to-noise ratio at ultra-high field MRI.

Authors:  Bei Zhang; Gregor Adriany; Lance Delabarre; Jerahmie Radder; Russell Lagore; Brian Rutt; Qing X Yang; Kamil Ugurbil; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2021-01-19       Impact factor: 3.737

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.