Literature DB >> 8748483

Validation of volume flow measurements with cine phase-contrast MR imaging for peripheral arterial waveforms.

T R McCauley1, C S Peña, C K Holland, T B Price, J C Gore.   

Abstract

A flow phantom was used to study MR volume flow measurements for monophasic and triphasic waveforms over the flow range expected in peripheral arteries at rest and with exercise (2-24 mL/sec, n = 50). The improvement in accuracy with phase-correction image processing to eliminate errors caused by eddy currents was measured. Volume flow estimates with Doppler sonography were also measured. MR volume flow measurements correlated with volume collection with r = .996 and mean error = 4.6%. Phase-correction processing decreased mean error from 12.6% to 4.6% (P < .001, paired t-test). Doppler sonography had a higher mean error of 10.3% (P < .001, unpaired t-test). Cine phase-contrast MR imaging provides accurate estimates of volume blood flow for waveforms and flow ranges expected in peripheral arteries.

Mesh:

Year:  1995        PMID: 8748483     DOI: 10.1002/jmri.1880050608

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

2.  Accuracy and reproducibility of phase-contrast MR imaging measurements for CSF flow.

Authors:  Andrew L Wentland; O Wieben; F R Korosec; V M Haughton
Journal:  AJNR Am J Neuroradiol       Date:  2010-03-04       Impact factor: 3.825

3.  In vitro validation of finite-element model of AAA hemodynamics incorporating realistic outlet boundary conditions.

Authors:  Ethan O Kung; Andrea S Les; Francisco Medina; Ryan B Wicker; Michael V McConnell; Charles A Taylor
Journal:  J Biomech Eng       Date:  2011-04       Impact factor: 2.097

4.  In Vitro Validation of Patient-Specific Hemodynamic Simulations in Coronary Aneurysms Caused by Kawasaki Disease.

Authors:  Ethan Kung; Andrew M Kahn; Jane C Burns; Alison Marsden
Journal:  Cardiovasc Eng Technol       Date:  2014-06-01       Impact factor: 2.495

5.  Accuracy of 4D Flow Measurement of Cerebrospinal Fluid Dynamics in the Cervical Spine: An In Vitro Verification Against Numerical Simulation.

Authors:  Soroush Heidari Pahlavian; Alexander C Bunck; Suraj Thyagaraj; Daniel Giese; Francis Loth; Dennis M Hedderich; Jan Robert Kröger; Bryn A Martin
Journal:  Ann Biomed Eng       Date:  2016-04-04       Impact factor: 3.934

6.  Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study.

Authors:  Emily A Aherne; Ioannis Koktzoglou; Benjamin B Lind; Robert R Edelman
Journal:  J Cardiovasc Magn Reson       Date:  2019-09-02       Impact factor: 5.364

7.  Interactions between Flow Oscillations and Biochemical Parameters in the Cerebrospinal Fluid.

Authors:  Vincent Puy; Jadwiga Zmudka-Attier; Cyrille Capel; Roger Bouzerar; Jean-Marie Serot; Anne-Marie Bourgeois; Jérome Ausseil; Olivier Balédent
Journal:  Front Aging Neurosci       Date:  2016-06-29       Impact factor: 5.750

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.