Literature DB >> 8747940

Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device.

A Bel1, R Keus, R E Vijlbrief, J V Lebesque.   

Abstract

The first aim of this study was to quantify estimated translational setup deviations of patients treated with a wedged pair of oblique beams for parotid gland and tonsillar tumors, using portal imaging. The second aim was to design an off-line setup verification procedure, to improve the setup accuracy, if necessary. Thirty-one patients were treated with two conformal fields (anterior-oblique and posterior-oblique). The patients were immobilized with a head cast. For the last 10 patients, the rigidity of the cast was improved while, in addition, wax molds with metal markers were placed into the outer ear for image correlation. Portal images were acquired about weekly. Setup deviations were analyzed, using anatomical structures and, when available, metal markers for image matching. The consistency of the deviations was determined by the correlation between deviations in the cranio-caudal direction, as measured from both beams. When the deviations were consistent, the translational setup deviation during a treatment session could be described by a three-dimensional (3D) vector. A setup verification procedure was designed using a computer simulation. The statistics of the 3D setup deviations were used as input. The output consisted of the resulting setup accuracy and workload (i.e., the number of setup corrections and portal images). Using the anatomical structures for image correlation, the deviations in the cranio-caudal direction were not correlated, either for the old or the improved cast. However, by using the metal markers, the deviations were correlated and a 3D analysis could be performed. The standard deviations, averaged over the three directions, were equal to 1.8 and 1.4 mm for the distribution of systematic and random deviations, respectively. Application of a setup verification procedure, with 0.7 corrections on the average per patient, could potentially reduce the percentage of 3D systematic deviations larger than 4 mm from 30 to 2%. It can be concluded that it was not possible to obtain consistent translational setup deviations, due to rotations. To quantify 3D translational setup deviations, it was necessary to use additional metal markers, which were visible in the portal images of both beams. A further improvement of the setup accuracy is possible by using an off-line setup verification procedure.

Entities:  

Mesh:

Year:  1995        PMID: 8747940     DOI: 10.1016/0167-8140(95)01627-s

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  12 in total

Review 1.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

2.  Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Authors:  Eva M Lozano; Luis A Pérez; Javier Torres; Carmen Carrascosa; Miguel Sanz; Fermín Mendicote; Antonio Gil
Journal:  Clin Transl Oncol       Date:  2011-01       Impact factor: 3.405

3.  A survey of image-guided radiation therapy use in the United States.

Authors:  Daniel R Simpson; Joshua D Lawson; Sameer K Nath; Brent S Rose; Arno J Mundt; Loren K Mell
Journal:  Cancer       Date:  2010-08-15       Impact factor: 6.860

4.  Adaptive radiation therapy for head and neck cancer-can an old goal evolve into a new standard?

Authors:  David L Schwartz; Lei Dong
Journal:  J Oncol       Date:  2010-08-18       Impact factor: 4.375

5.  Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?

Authors:  Jennifer C O'Daniel; Adam S Garden; David L Schwartz; He Wang; Kian K Ang; Anesa Ahamad; David I Rosenthal; William H Morrison; Joshua A Asper; Lifei Zhang; Shih-Ming Tung; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-15       Impact factor: 7.038

6.  Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging.

Authors:  Imad Ali; Jesse Tubbs; Kerry Hibbitts; Ozer Algan; Spencer Thompson; Terence Herman; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2010-05-20       Impact factor: 2.102

7.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

8.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

9.  Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system.

Authors:  Giuseppe Minniti; Maurizio Valeriani; Enrico Clarke; Marco D'Arienzo; Michelangelo Ciotti; Roberto Montagnoli; Francesca Saporetti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2010-01-13       Impact factor: 3.481

10.  Impact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: the need for a planning target volume and a planning organ-at-risk volume.

Authors:  O Ballivy; W Parker; T Vuong; G Shenouda; H Patrocinio
Journal:  Curr Oncol       Date:  2006-06       Impact factor: 3.677

View more