the "Ulm Zucker Uhr System" and its consequences.

E F Pfeiffer1.   

Abstract

The "Ulm Zucker Uhr System" comprises a microdialysis probe, a biosensor (Glucosensor Unitec Ulm s.c.), a sender transferring telemetrically the glucose concentrations, and a receiving indicator. The "Zucker Uhr" or "Sugar Watch" looks and operates like a normal wrist watch. We now present the functioning pre-prototype of the first portable system, which 1) is continuously measuring in s.c. tissue the Tissue Glucose (T.G.) concentration in the intercellular fluid on-line enzymatically by combining an enzymatic and an electrochemical (amperometric) technique. 2) is transferring in the patient via the "Zucker Uhr" once per minute the actual tissue glucose concentration, i.e. 1,440 values/24 hours or even 2880 values/48 hours, 3) is actually alarming the patient by optical and acoustic means, when the tissue glucose is too high (hyperglycemia) or too low (hypoglycemia), 4) is storing digitally all values and, therefore, permitting the dialogue between doctor and patient as to his diabetes control in view of his 24 h glucose profile, which is visual on a computer screen. The advantage for the patient is on the one hand the elimination of the multiple pricking in the finger tips for providing capillary blood, and on the other hand, permitting the preview of the limitation and perhaps the complete elimination of the microangiopathy of the retina, kidneys and nervous system. The trend of the T.G. decreases is readily recognizable, which indicates immediately the dangerous hypoglycemia. Likewise, over 48 hours, the hyperglycemic periods are transmitted and recorded which are not measured and reflected by the HbA1 and HbA1c conventional measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7875644     DOI: 10.1055/s-2007-1001746

Source DB:  PubMed          Journal:  Horm Metab Res        ISSN: 0018-5043            Impact factor:   2.936


  3 in total

Review 1.  Does fall in tissue glucose precede fall in blood glucose?

Authors:  F Sternberg; C Meyerhoff; F J Mennel; H Mayer; F Bischof; E F Pfeiffer
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

2.  Use of microdialysis-based continuous glucose monitoring to drive real-time semi-closed-loop insulin infusion.

Authors:  Guido Freckmann; Nina Jendrike; Stefan Pleus; Harvey Buck; Steven Bousamra; Paul Galley; Ajay Thukral; Robin Wagner; Stefan Weinert; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2014-09-09

Review 3.  Effect of divergent continuous glucose monitoring technologies on glycaemic control in type 1 diabetes mellitus: A systematic review and meta-analysis of randomised controlled trials.

Authors:  Mona Elbalshy; Jillian Haszard; Hazel Smith; Sarahmarie Kuroko; Barbara Galland; Nick Oliver; Viral Shah; Martin I de Bock; Benjamin J Wheeler
Journal:  Diabet Med       Date:  2022-04-25       Impact factor: 4.213

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.