Literature DB >> 8724469

Sensitivity of the Jamar Dynamometer in detecting submaximal grip effort.

R F Ashford1, S Nagelburg, R Adkins.   

Abstract

Twenty-two people with no extremity disability were tested in a standard fashion using the Jamar Dynamometer to establish their maximum grip strength. Each participant was asked to grip first right-handed then left-handed three consecutive times. The directions were reexplained so that each participant would give a consistent, less than optimal effort; three trials right and three trials left were recorded. The standard deviations of each set of these trials were calculated for both right and left hands. These standard deviations were then tabulated as scores for 44 trials of 22 patients, both hands, for maximal and submaximal efforts. These scores were then compared, maximal versus submaximal, using a paired t-test. We found no statistical difference in the two groups in comparing the variability of results. Therefore, the current protocol for Jamar testing can allow a patient to make a consistently submaximal effort, resulting in a false apparent loss of grip strength.

Entities:  

Mesh:

Year:  1996        PMID: 8724469     DOI: 10.1016/S0363-5023(96)80352-2

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  10 in total

1.  Baseline characteristics of participants in the VITamin D and OmegA-3 TriaL (VITAL): Effects on Bone Structure and Architecture.

Authors:  Catherine M Donlon; Meryl S LeBoff; Sharon H Chou; Nancy R Cook; Trisha Copeland; Julie E Buring; Vadim Bubes; Gregory Kotler; JoAnn E Manson
Journal:  Contemp Clin Trials       Date:  2018-02-23       Impact factor: 2.226

2.  The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

Authors:  Ian Gatt; Sophie Smith-Moore; Charlie Steggles; Mike Loosemore
Journal:  Hand (N Y)       Date:  2017-05-10

Review 3.  [Grip strength measurement : Significance and boundaries].

Authors:  P Hahn; C Spies; F Unglaub; M Mühldorfer-Fodor
Journal:  Orthopade       Date:  2018-03       Impact factor: 1.087

4.  Sex Differences in Recovery Across Multiple Domains Among Older Adults With Hip Fracture.

Authors:  Denise L Orwig; Danielle S Abraham; Marc C Hochberg; Ann Gruber-Baldini; Jack M Guralnik; Anne R Cappola; Justine Golden; Gregory E Hicks; Ram R Miller; Barbara Resnick; Michelle Shardell; Robert S Sterling; Rashmita Bajracharya; Jay Magaziner
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2022-07-05       Impact factor: 6.591

5.  Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function.

Authors:  Barbara Resnick; Ann L Gruber-Baldini; Gregory Hicks; Glen Ostir; N Jennifer Klinedinst; Denise Orwig; Jay Magaziner
Journal:  Rehabil Nurs       Date:  2015-10-23       Impact factor: 1.625

6.  The impact of body composition, pain and resilience on physical activity, physical function and physical performance at 2 months post hip fracture.

Authors:  Barbara Resnick; J Richard Hebel; Ann L Gruber-Baldini; Gregory E Hicks; Marc C Hochberg; Denise Orwig; Marty Eastlack; Jay Magaziner
Journal:  Arch Gerontol Geriatr       Date:  2018-02-15       Impact factor: 3.250

7.  Grip strength measured by high precision dynamometry in healthy subjects from 5 to 80 years.

Authors:  Jean-Yves Hogrel
Journal:  BMC Musculoskelet Disord       Date:  2015-06-10       Impact factor: 2.362

8.  Frailty among institutionalized older people: a cross-sectional study in Natal (Brazil).

Authors:  Fabienne Louise Juvêncio Paes de Andrade; Javier Jerez-Roig; Louise Natália Mesquita Belém; Kenio Costa de Lima
Journal:  J Frailty Sarcopenia Falls       Date:  2019-06-01

9.  Ultrasound evaluation in combination with finger extension force measurements of the forearm musculus extensor digitorum communis in healthy subjects.

Authors:  Sofia Brorsson; Anna Nilsdotter; Marita Hilliges; Christer Sollerman; Ylva Aurell
Journal:  BMC Med Imaging       Date:  2008-03-03       Impact factor: 1.930

10.  Determining Sincerity of Effort Based on Grip Strength Test in Three Wrist Positions.

Authors:  Petcharatana Bhuanantanondh; Pirun Nanta; Keerin Mekhora
Journal:  Saf Health Work       Date:  2017-06-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.