Literature DB >> 8706547

Evaluation of several immunological parameters in patients with aseptic loosening of hip arthroplasty.

D Granchi1, G Ciapetti, S Stea, D Cavedagna, N Bettini, T Bianco, G Fontanesi, A Pizzoferrato.   

Abstract

The authors evaluated several immunological parameters in patients with loosened hip arthroplasty in order to determine the state of sensitization with regard to the metallic constituents of the prosthesis. The results obtained by in vivo epicutaneous testing did not reveal a correlation between loosening and sensitization, as the patch test was positive in only 1 out of 16 cases examined. An evaluation of the lymphocyte subpopulation on peripheral blood demonstrated that patients with prostheses in Cr, Co, Mo, Ni alloy present significant lymphopenia, with a reduction in subpopulations CD4 and CD8 and a decrease in in vitro cytotoxic activity. The meaning of these modifications could be interpreted to be either a toxic effect products released from the implant, or as the recruitment of lymphocytes in the site of loosening, due to lymphocyte sequestration phenomena consequent to a cell-mediated hypersensitivity reaction.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8706547

Source DB:  PubMed          Journal:  Chir Organi Mov        ISSN: 0009-4749


  10 in total

1.  Management of failed metal-on-metal total hip arthroplasty.

Authors:  Justin W Griffin; Michele D'Apuzzo; James A Browne
Journal:  World J Orthop       Date:  2012-06-18

2.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 3.  The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses.

Authors:  Peter A Revell
Journal:  J R Soc Interface       Date:  2008-11-06       Impact factor: 4.118

4.  Do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations?

Authors:  Isabelle Catelas; Eric A Lehoux; Ian Hurda; Stephen J Baskey; Luca Gala; Ryan Foster; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

5.  Serum levels of interleukin 6 (IL-6), granulocyte-macrophage colony-stimulating factor (GM-CSF) and elastase in aseptic prosthetic loosening.

Authors:  Nikolaus A Streich; Steffen J Breusch; Ulrich Schneider
Journal:  Int Orthop       Date:  2003-07-15       Impact factor: 3.075

6.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

7.  Wear particles, periprosthetic osteolysis and the immune system.

Authors:  Stuart B Goodman
Journal:  Biomaterials       Date:  2007-07-23       Impact factor: 12.479

8.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

9.  Increased expression of inducible co-stimulator on CD4+ T-cells in the peripheral blood and synovial fluid of patients with failed hip arthroplasties.

Authors:  P A Revell; G S Matharu; S Mittal; P B Pynsent; C D Buckley; M P Revell
Journal:  Bone Joint Res       Date:  2016-02       Impact factor: 5.853

Review 10.  The Inflammatory Effects of Breast Implant Particulate Shedding: Comparison With Orthopedic Implants.

Authors:  Nadim James Hallab; Lauryn Samelko; Dennis Hammond
Journal:  Aesthet Surg J       Date:  2019-01-31       Impact factor: 4.283

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.