Literature DB >> 8702373

The reliability, validity, and stability of a measure of physical activity in the elderly.

G Kochersberger1, E McConnell, M N Kuchibhatla, C Pieper.   

Abstract

OBJECTIVE: To assess the reliability, validity, and stability of an accelerometer-based monitor of physical activity in an elderly population.
DESIGN: Six studies were conducted to assess the Tritrac, a newly available accelerometer capable of storing three-dimensional activity data collected in minute epochs. After initial bench testing, the waist-worn devices were assessed for test-retest reliability during sitting and treadmill walking at 1mph and 2mph. Validity testing examined the Tritrac's ability to discriminate between different levels of physical activity and also compared the Tritrac with an established wrist-worn acclerometer, the Actigraph. Stability of the measure was examined over a period of 3 to 7 days, and in a subset of subjects this measurement was performed for a second week. SETTING AND
SUBJECTS: Residents of a VA Nursing Home (n = 40; mean age = 76), participants in an in-home nonaerobic exercise program (n = 36; mean age = 77), and community participants in an aerobic exercise program (n = 10; mean age = 71).
RESULTS: Intraclass correlation coefficients (ICC) for both the bench testing and test-retest reliability were .97. The device discriminated among subjects independently categorized as sedentary, moderately active, or active (F = 49.4, p = .0001) and between specific activities of varying intensity (F = 114.5, p = .0001). Tritrac and Actigraph measurement comparison showed a correlation of r = .77, p = .0001. Stability of the measure was demonstrated by ICCs = .81 and .78 for mean activity values and proportion of time spent in sedentary activity, respectively. No significant differences were observed when comparing activity measured for two separate weeks.
CONCLUSION: The Tritrac is a reliable and valid instrument producing activity measurement that was stable over time in the elderly population we studied. During our longitudinal testing, 20% of the subjects did not comply with wearing the device; this noncompliance issue must be considered in any use of the Tritrac.

Entities:  

Mesh:

Year:  1996        PMID: 8702373     DOI: 10.1016/s0003-9993(96)90258-0

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  28 in total

1.  Computerized monitoring of physical activity and sleep in postoperative abdominal surgery patients.

Authors:  T Bisgaard; M Kjaersgaard; A Bernhard; H Kehlet; J Rosenberg
Journal:  J Clin Monit Comput       Date:  1999-01       Impact factor: 2.502

2.  Activity monitoring and energy expenditure in COPD patients: a validation study.

Authors:  Sanjay A Patel; Roberto P Benzo; William A Slivka; Frank C Sciurba
Journal:  COPD       Date:  2007-06       Impact factor: 2.409

3.  Context awareness of human motion states using accelerometer.

Authors:  Gye Hwan Jin; Sang Bock Lee; Tae Soo Lee
Journal:  J Med Syst       Date:  2008-04       Impact factor: 4.460

4.  Treadmill gait speeds correlate with physical activity counts measured by cell phone accelerometers.

Authors:  Richard H Carlson; Derek R Huebner; Carrie A Hoarty; Jackie Whittington; Gleb Haynatzki; Michele C Balas; Ana Katrin Schenk; Evan H Goulding; Jane F Potter; Stephen J Bonasera
Journal:  Gait Posture       Date:  2012-04-02       Impact factor: 2.840

Review 5.  Position-sensing technologies for movement analysis in stroke rehabilitation.

Authors:  H Zheng; N D Black; N D Harris
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

6.  Habitual physical activity levels are associated with performance in measures of physical function and mobility in older men.

Authors:  Marina Morie; Kieran F Reid; Renee Miciek; Newsha Lajevardi; Karen Choong; Joanne B Krasnoff; Thomas W Storer; Roger A Fielding; Shalender Bhasin; Nathan K Lebrasseur
Journal:  J Am Geriatr Soc       Date:  2010-08-24       Impact factor: 5.562

7.  Measurement of daily physical activity using the SenseWear Armband: Compliance, comfort, adverse side effects and usability.

Authors:  Renae J McNamara; Ling Ling Y Tsai; Sally L Wootton; L W Cindy Ng; Marita T Dale; Zoe J McKeough; Jennifer A Alison
Journal:  Chron Respir Dis       Date:  2016-02-15       Impact factor: 2.444

8.  Practical guide to measuring physical activity.

Authors:  Louisa G Sylvia; Emily E Bernstein; Jane L Hubbard; Leigh Keating; Ellen J Anderson
Journal:  J Acad Nutr Diet       Date:  2013-11-28       Impact factor: 4.910

9.  Effect of perindopril on physical function in elderly people with functional impairment: a randomized controlled trial.

Authors:  Deepa Sumukadas; Miles D Witham; Allan D Struthers; Marion E T McMurdo
Journal:  CMAJ       Date:  2007-10-09       Impact factor: 8.262

10.  Seasonal changes in amount and patterns of physical activity in women.

Authors:  Maciej S Buchowski; Leena Choi; Karen M Majchrzak; Sari Acra; Charles E Mathews; Kong Y Chen
Journal:  J Phys Act Health       Date:  2009-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.