Literature DB >> 8685261

A comparison of dosimetry techniques in stereotactic radiosurgery.

M Heydarian1, P W Hoban, A H Beddoe.   

Abstract

Accurate dosimetry of small-field photon beams used in stereotactic radiosurgery (SRS) can be made difficult because of the presence of lateral electronic disequilibrium and steep dose gradients. In the published literature, data acquisition for radiosurgery is mainly based on diode and film dosimetry, and sometimes on small ionization chamber or thermolominescence dosimetry. These techniques generally do not provide the required precision because of their energy dependence and/or poor resolution. In this work PTW diamond detectors and Monte Carlo (EGS4) techniques have been added to the above tools to measure and calculate SRS treatment planning requirements. The validity of the EGS4 generated data has been confirmed by comparing results to those obtained with an ionization chamber, where the field size is large enough for electronic equilibrium to be established at the central axis. Using EGS4 calculations, the beam characteristics under the experimental conditions have also been quantified. It was shown that diamond detectors are potentially ideal for SRS and yield more accurate results than the above traditional modes of dosimetry.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8685261     DOI: 10.1088/0031-9155/41/1/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Evaluation of beam modeling for small fields using a flattening filter-free beam.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Takeo Nakashima; Masamichi Aita; Shintaro Tsuda; Yusuke Ochi; Takuro Okumura; Hirokazu Masuda; Yoshimi Ohno; Yuji Murakami; Yasushi Nagata
Journal:  Radiol Phys Technol       Date:  2016-06-21

4.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

5.  Investigating end-to-end accuracy of image guided radiation treatment delivery using a micro-irradiator.

Authors:  L J Rankine; J Newton; S T Bache; S K Das; J Adamovics; D G Kirsch; M Oldham
Journal:  Phys Med Biol       Date:  2013-10-18       Impact factor: 3.609

6.  Dosimetric comparison of linear accelerator-based stereotactic radiosurgery systems.

Authors:  S D Sharma; Sudhir Kumar; S S Dagaonkar; Geetika Bisht; S Dayanand; Reena Devi; S S Deshpande; S Chaudhary; B C Bhatt; S Kannan
Journal:  J Med Phys       Date:  2007-01

7.  Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.

Authors:  Henry Finlay Godson; M Ravikumar; S Sathiyan; K M Ganesh; Y Retna Ponmalar; C Varatharaj
Journal:  J Med Phys       Date:  2016 Jan-Mar

8.  The influence of field size on stopping-power ratios in- and out-of-field: quantitative data for the BrainLAB m3 micro-multileaf collimator.

Authors:  Michael Taylor; Tanya Kairn; Tomas Kron; Leon Dunn; Peter N Johnston; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

10.  Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.

Authors:  Guerda Massillon-J L; Diego Cueva-Prócel; Porfirio Díaz-Aguirre; Miguel Rodríguez-Ponce; Flor Herrera-Martínez
Journal:  PLoS One       Date:  2013-05-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.