Literature DB >> 8660107

Interobserver reliability in measuring flexion, internal rotation, and external rotation of the hip using a plurimeter.

P R Croft1, E S Nahit, G J Macfarlane, A J Silman.   

Abstract

OBJECTIVE: To determine reliability of the measurement of hip movements (flexion, internal rotation, and external rotation) between medical practitioners.
METHODS: Six clinicians carried out measurements of hip movements on each of six patients with osteoarthritis of one hip, using a specifically designed plurimeter.
RESULTS: There was no evidence of any systematic difference between medical practitioners in the measurement of hip flexion, internal rotation, or external rotation. The degree of agreement was greatest for hip flexion.
CONCLUSIONS: This study has shown that measurement of range of movement at the hip is repeatable between practitioners using a simple plurimeter and may represent an examination that is suitable for monitoring progress and treatment.

Entities:  

Mesh:

Year:  1996        PMID: 8660107      PMCID: PMC1010170          DOI: 10.1136/ard.55.5.320

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  1 in total

1.  Reliability of skin involvement measures in scleroderma. The UK Scleroderma Study Group.

Authors:  P Brennan; A Silman; C Black; R Bernstein; J Coppock; P Maddison; T Sheeran; C Stevens; F Wollheim
Journal:  Br J Rheumatol       Date:  1992-07
  1 in total
  9 in total

1.  No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

Authors:  Wierd P Zijlstra; Inge van den Akker-Scheek; Mark J M Zee; Jos J A M van Raay
Journal:  Int Orthop       Date:  2011-03-04       Impact factor: 3.075

2.  Factors associated with hip joint rotation in former elite athletes.

Authors:  J A Kettunen; U M Kujala; H Räty; T Videman; S Sarna; O Impivaara; S Koskinen
Journal:  Br J Sports Med       Date:  2000-02       Impact factor: 13.800

3.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

4.  Hip pain and mobility deficits--hip osteoarthritis: clinical practice guidelines linked to the international classification of functioning, disability, and health from the orthopaedic section of the American Physical Therapy Association.

Authors:  Michael T Cibulka; Douglas M White; Judith Woehrle; Marcie Harris-Hayes; Keelan Enseki; Timothy L Fagerson; James Slover; Joseph J Godges
Journal:  J Orthop Sports Phys Ther       Date:  2009-04       Impact factor: 4.751

5.  Reliability of hip internal rotation range of motion measurement using a digital inclinometer.

Authors:  David A Krause; John H Hollman; Aaron J Krych; Michael M Kalisvaart; Bruce A Levy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

6.  Defining hip pain for population studies.

Authors:  F Birrell; M Lunt; G J Macfarlane; A J Silman
Journal:  Ann Rheum Dis       Date:  2005-01       Impact factor: 19.103

7.  Intertester and intratester reliability of movement control tests on the hip for patients with hip osteoarthritis.

Authors:  Rahel Lenzlinger-Asprion; Niculina Keller; André Meichtry; Hannu Luomajoki
Journal:  BMC Musculoskelet Disord       Date:  2017-01-31       Impact factor: 2.362

8.  Predictors of hip joint replacement in new attenders in primary care with hip pain.

Authors:  Fraser Birrell; Cara Afzal; Elizabeth Nahit; Mark Lunt; Gary J Macfarlane; Cyrus Cooper; Peter R Croft; Gillian Hosie; Alan J Silman
Journal:  Br J Gen Pract       Date:  2003-01       Impact factor: 5.386

9.  Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis - an inter-rater study.

Authors:  Erik Poulsen; Henrik Wulff Christensen; Jeannette Østergaard Penny; Søren Overgaard; Werner Vach; Jan Hartvigsen
Journal:  BMC Musculoskelet Disord       Date:  2012-12-06       Impact factor: 2.362

  9 in total