Reliability of hip internal rotation range of motion measurement using a digital inclinometer.

David A Krause1, John H Hollman, Aaron J Krych, Michael M Kalisvaart, Bruce A Levy.   

Abstract

PURPOSE: Assessment of hip internal rotation (IR) is a critical element in the evaluation of a painful hip, yet there currently exists no consistent method of determining this measurement. The purpose of this study is to report the intra-rater and inter-rater reliability of active and passive hip IR measurement using a digital inclinometer.
METHODS: Twenty-five subjects (8 men, 17 women) with asymptomatic hip joints, and no known pathology between the ages of 22 and 42 participated. Two examiners measured hip IR for each subject using a digital inclinometer while visually monitoring pelvic motion. Measurements included passive IR, active IR, and active IR while internally rotating both legs simultaneously. Statistical analysis was performed including intra-rater and inter-rater reliability.
RESULTS: There was no significant difference in measured IR values. Mean range of motion values for all techniques and both examiners ranged from 30.7° to 32.8°. Intra-rater reliability for examiner 1 ranged from 0.84 to 0.92. Inter-rater reliability ranged from 0.89 to 0.93. Of the methods utilized, active IR of a single leg was the most responsive technique with a minimal detectable change value of 5.4°.
CONCLUSIONS: Clinical assessment of hip IR range of motion can be performed efficiently and reliably with a digital inclinometer along with visual monitoring of the pelvis for unwanted motion. Findings from this study support unilateral active hip IR in a seated position as a reliable and responsive technique for obtaining hip IR measurements.

Entities:  

Mesh:

Year:  2014        PMID: 24912575     DOI: 10.1007/s00167-014-3096-0

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  18 in total

1.  Reliability of the dial test using a handheld inclinometer.

Authors:  David A Krause; Bruce A Levy; Jay P Shah; Michael J Stuart; John H Hollman; Diane L Dahm
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-13       Impact factor: 4.342

2.  The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report.

Authors:  Morey J Kolber; William J Hanney
Journal:  Int J Sports Phys Ther       Date:  2012-06

Review 3.  Hip arthroscopy in the athletic patient: current techniques and spectrum of disease.

Authors:  Michael K Shindle; James E Voos; Benton E Heyworth; Douglas N Mintz; Luis E Moya; Robert L Buly; Bryan T Kelly
Journal:  J Bone Joint Surg Am       Date:  2007-10       Impact factor: 5.284

Review 4.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

5.  An examination chair to measure internal rotation of the hip in routine settings: a validation study.

Authors:  S Reichenbach; P Jüni; E Nüesch; F Frey; R Ganz; M Leunig
Journal:  Osteoarthritis Cartilage       Date:  2009-10-08       Impact factor: 6.576

6.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

7.  Three-dimensional assessment of cam engagement in femoroacetabular impingement.

Authors:  Emmanuel A Audenaert; Peter Mahieu; Christophe Pattyn
Journal:  Arthroscopy       Date:  2010-10-16       Impact factor: 4.772

8.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

9.  Intrarater test-retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis.

Authors:  Yong-Hao Pua; Tim V Wrigley; Tim W Wrigley; Sallie M Cowan; Kim L Bennell
Journal:  Arch Phys Med Rehabil       Date:  2008-06       Impact factor: 3.966

10.  Decreased range of motion is associated with structural hip deformity in asymptomatic adolescent athletes.

Authors:  Brandon J Yuan; Robert B Bartelt; Bruce A Levy; Jeffrey R Bond; Robert T Trousdale; Rafael J Sierra
Journal:  Am J Sports Med       Date:  2013-05-22       Impact factor: 6.202

View more
  6 in total

1.  Differences in hip range of motion among collegiate pitchers when compared to youth and professional baseball pitcher data.

Authors:  Scott W Cheatham; Kathryn Kumagai Shimamura; Morey J Kolber
Journal:  J Can Chiropr Assoc       Date:  2016-09

2.  Regional interdependence of the hip and lumbo-pelvic region in divison ii collegiate level baseball pitchers: a preliminary study.

Authors:  Kathryn Kumagai Shimamura; Scott Cheatham; Wendy Chung; Daniel Farwell; Francisco De la Cruz; Jennifer Goetz; Kaleigh Lindblom; Darcy Powers
Journal:  Int J Sports Phys Ther       Date:  2015-02

3.  Reliability of hip range of motion measurement among experienced arthroscopic hip preservation surgeons.

Authors:  Joshua D Harris; Richard C Mather; Shane J Nho; John P Salvo; Allston J Stubbs; Geoffrey S Van Thiel; Andrew B Wolff; John J Christoforetti; Thomas J Ellis; Dean K Matsuda; Benjamin R Kivlan; Dominic S Carreira
Journal:  J Hip Preserv Surg       Date:  2019-12-12

4.  MEASUREMENT OF PELVIC RETROVERSION DURING HIP FLEXION: EVALUATION WITH ACCELEROMETERS.

Authors:  Alexandre Fenato; Larissa Martins Garcia; Gleici DA Silva Castro Perdoná; Daniel Augusto Maranho
Journal:  Acta Ortop Bras       Date:  2020 Mar-Apr       Impact factor: 0.513

5.  Less hip range of motion is associated with a greater alpha angle in people with longstanding hip and groin pain.

Authors:  August Estberger; Anders Pålsson; Ioannis Kostogiannis; Eva Ageberg
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-09-12       Impact factor: 4.342

6.  Feasibility and reliability of a web-based smartphone application for joint position measurement.

Authors:  Bharadwaj Ravi; Manak Kapoor; Darren Player
Journal:  J Rehabil Med       Date:  2021-05-10       Impact factor: 2.912