Literature DB >> 8623633

T2-weighted spin-echo MR imaging of the liver: breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression.

P Soyer1, S Le Normand, S C de Givry, C Gueye, E Somveille, A Scherrer.   

Abstract

OBJECTIVE: The goal of our study was to compare a T2-weighted breath-hold fast spin-echo (BHSE) technique with T2-weighted non-breath-hold fast spin-echo techniques for imaging the liver. SUBJECTS AND METHODS: Thirty-three patients with hepatic lesions had T2-weighted BHSE images obtained in 22 sec and conventional T2-weighted non-breath-hold fast spin-echo images obtained in 3 min 12 sec with and without fat suppression. Images were analyzed quantitatively by measuring the lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios of lesions and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and presence of artifacts.
RESULTS: Quantitatively, lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios obtained with the BHSE technique were inferior to those obtained with fast spin-echo techniques with and without fat suppression (11.2 +/- 7.1 versus 15.4 +/- 10.6 and 14.5 +/- 9.8, p < .001; 5.3 +/- 3.7 versus 8.7 +/- 3.5 and 7.0 +/- 3.8, p < .001; 16.2 +/- 8.2 versus 20.1 +/- 10.9 and 19.7 +/- 9.5, p < .01, respectively; Student's t test). Qualitatively, image artifacts and intrahepatic vessel depiction on BHSE images were similar to those obtained with the fast spin-echo techniques. The BHSE technique was superior to fat-suppressed fast spin-echo technique for showing hepatic contours (p < .01; Wilcoxon signed-rank test).
CONCLUSION: The BHSE technique is quantitatively inferior to non-breath-hold fast spin-echo techniques. However, further studies with a surgical standard of reference are needed to compare the three techniques in terms of sensitivity.

Entities:  

Mesh:

Year:  1996        PMID: 8623633     DOI: 10.2214/ajr.166.3.8623633

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging.

Authors:  T K Helmberger; J Schröder; N Holzknecht; M Gregor; A Heuck; R Petsch; M F Reiser
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

2.  Detection of focal hepatic lesions with 3-T MRI: comparison of two-dimensional and three-dimensional T2-weighted sequences.

Authors:  Haruo Watanabe; Masayuki Kanematsu; Satoshi Goshima; Hiroshi Kondo; Kimihiro Kajita; Hiroshi Kawada; Yoshifumi Noda; Noriyuki Moriyama
Journal:  Jpn J Radiol       Date:  2012-08-22       Impact factor: 2.374

  2 in total