Literature DB >> 22907739

Detection of focal hepatic lesions with 3-T MRI: comparison of two-dimensional and three-dimensional T2-weighted sequences.

Haruo Watanabe1, Masayuki Kanematsu, Satoshi Goshima, Hiroshi Kondo, Kimihiro Kajita, Hiroshi Kawada, Yoshifumi Noda, Noriyuki Moriyama.   

Abstract

PURPOSE: To evaluate whether incorporation of a 3D turbo spin-echo sequence during T2-weighted MR imaging improves the detection of focal hepatic lesions by 3T MR imaging.
MATERIALS AND METHODS: Seventy-nine consecutive patients including 67 patients with 62 malignant and 71 benign lesions and 12 patients having no hepatic lesion underwent respiratory-triggered fat-suppressed axial T2-weighted turbo spin-echo imaging using two-dimensional (2D-TSE) and 3D (3D-TSE) sequences. Coronal multiplanar reformatted images (MPR-3D-TSE) were generated from 3D-TSE images. Breath-hold fat-suppressed 2D axial T2-weighted half-Fourier turbo spin-echo (HF-2D-TSE) images were combined for reading. Two independent radiologists reviewed three imaging sets, (1) 2D-TSE and HF-2D-TSE, (2) 3D-TSE and HF-2D-TSE, and (3) 3D-TSE, HF-2D-TSE and MPR-3D-TSE, for detection of malignant and benign lesions. Lesion-to-liver contrast ratio (CR) and the conspicuity of anatomical boundaries were assessed.
RESULTS: For benign lesions, lesion-to-liver CRs with 3D-TSE (2.77 ± 1.91, p = .0002) and MPR-3D-TSE (2.47 ± 1.42, p = .012) were higher than with 2D-TSE (2.13 ± 1.80). Sensitivity for lesions of ≤ 10-mm was higher with 3D-TSE (86 %, p = .0039) and MPR-3D-TSE (84 %, p = .0078) than with 2D-TSE (72 %). However, the edge of left lateral lobe was less conspicuous with 3D-TSE (p < .0001) and MPR-3D-TSE (p = .0003) than with 2D-TSE because of susceptibility artifacts.
CONCLUSION: Incorporation of 3D T2-weighted sequence may incrementally improve the detection of focal hepatic lesions.

Entities:  

Mesh:

Year:  2012        PMID: 22907739     DOI: 10.1007/s11604-012-0111-6

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  15 in total

1.  Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences.

Authors:  Joelle Augui; Olivier Vignaux; Christophe Argaud; Joel Coste; Hervé Gouya; Paul Legmann
Journal:  Radiology       Date:  2002-06       Impact factor: 11.105

2.  Focal hepatic lesion detection: comparison of four fat-suppressed T2-weighted MR imaging pulse sequences.

Authors:  M Kanematsu; H Hoshi; K Itoh; T Murakami; M Hori; H Kondo; R Yokoyama; H Nakamura
Journal:  Radiology       Date:  1999-05       Impact factor: 11.105

3.  The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI.

Authors:  R T Constable; J C Gore
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

4.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

Authors:  Cedric M J de Bazelaire; Guillaume D Duhamel; Neil M Rofsky; David C Alsop
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

5.  Utility of breath-hold fast-recovery fast spin-echo t2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging.

Authors:  Jimmy Huang; Steven S Raman; Ngan Vuong; James W Sayre; David S K Lu
Journal:  AJR Am J Roentgenol       Date:  2005-03       Impact factor: 3.959

6.  Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions.

Authors:  Bong Soo Kim; Jung Hoon Kim; Guk Myung Choi; Seung Hyoung Kim; Ji Kang Park; Byung-Cheol Song; Weechang Kang
Journal:  AJR Am J Roentgenol       Date:  2008-01       Impact factor: 3.959

7.  T2-weighted spin-echo MR imaging of the liver: breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression.

Authors:  P Soyer; S Le Normand; S C de Givry; C Gueye; E Somveille; A Scherrer
Journal:  AJR Am J Roentgenol       Date:  1996-03       Impact factor: 3.959

8.  Chronic hepatitis: correlation of early patchy and late linear enhancement patterns on gadolinium-enhanced MR images with histopathology initial experience.

Authors:  R C Semelka; J J Chung; S M Hussain; H B Marcos; J T Woosley
Journal:  J Magn Reson Imaging       Date:  2001-03       Impact factor: 4.813

9.  Nontumorous hepatic arterial-portal venous shunts: MR imaging findings.

Authors:  J S Yu; K W Kim; M G Jeong; J T Lee; H S Yoo
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

10.  Qualitative and quantitative evaluation of hepatocellular carcinoma and cirrhotic liver enhancement using Gd-EOB-DTPA.

Authors:  Bernd B Frericks; Christoph Loddenkemper; Alexander Huppertz; Steffi Valdeig; Andrea Stroux; Marion Seja; Karl-Jürgen Wolf; Thomas Albrecht
Journal:  AJR Am J Roentgenol       Date:  2009-10       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.