Literature DB >> 8619381

Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for pediatric studies.

W W Koo1, J Walters, A J Bush.   

Abstract

Dual X-ray absorptiometry (DXA) measurements have been shown to provide useful information on bone mineral status in young pediatric subjects. The purpose of this study was to challenge this system under various conditions to determine the clinical and experimental parameters that may be encountered which could interfere with DXA-based bone mineral content (BMC) and bone mineral density (BMD) measurements. Variations in data acquisition, including the covering of step phantom (external calibration standard) with a cotton blanket or partial exclusion of step phantom in the scan field, tissue freezing, or the presence of small nonmetallic objects, did not significantly alter DXA BMC or BMD measurements. By contrast, the presence of movement artifact, radiographic contrast media, and nonmetallic orthopedic casts significantly interfered with DXA BMC and BMC measurements. Variability in operator-dependent analysis of DXA scans occurred with regional analysis of whole body scans for DXA BMC and BMD measurements (average coefficient of variation was 2.9% and 1%, respectively, depending on the region analyzed) but did not affect the total (whole body) result. A minor adjustment in the manual delineation of the step phantom during data analysis may result in almost a 30% difference in DXA BMC and BMD. We conclude that movement artifact, radiographic contrast media, nonmetallic or orthopedic cast, and variations in operator-dependent data analysis may interfere with DXA BMC and BMD measurement in young pediatric subjects. Therefore, appropriate care should be taken to reduce or eliminate such interference.

Entities:  

Mesh:

Year:  1995        PMID: 8619381     DOI: 10.1002/jbmr.5650101220

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  12 in total

Review 1.  Bone outcomes and technical measurement issues of bone health among children and adolescents: considerations for nutrition and physical activity intervention trials.

Authors:  Jayne A Fulkerson; John H Himes; Simone A French; Sally Jensen; Moira A Petit; Christy Stewart; Mary Story; Kristine Ensrud; Sandy Fillhouer; Kristine Jacobsen
Journal:  Osteoporos Int       Date:  2004-08-27       Impact factor: 4.507

2.  Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers.

Authors:  Nicola J Crabtree; N J Shaw; C M Boivin; B Oldroyd; J G Truscott
Journal:  Osteoporos Int       Date:  2005-10-19       Impact factor: 4.507

3.  Use of dual energy X-ray absorptiometry in pediatric patients.

Authors:  Halley Wasserman; Jennifer M O'Donnell; Catherine M Gordon
Journal:  Bone       Date:  2016-12-15       Impact factor: 4.398

4.  Optimal monitoring time interval between DXA measures in children.

Authors:  John A Shepherd; Li Wang; Bo Fan; Vicente Gilsanz; Heide J Kalkwarf; Joan Lappe; Ying Lu; Thomas Hangartner; Babette S Zemel; Margaret Fredrick; Sharon Oberfield; Karen K Winer
Journal:  J Bone Miner Res       Date:  2011-11       Impact factor: 6.741

5.  Placental size at 19 weeks predicts offspring bone mass at birth: findings from the Southampton Women's Survey.

Authors:  C R Holroyd; N C Harvey; S R Crozier; N R Winder; P A Mahon; G Ntami; K M Godfrey; H M Inskip; C Cooper
Journal:  Placenta       Date:  2012-05-27       Impact factor: 3.481

6.  Increased gain in bone mineral content of preterm infants fed an isocaloric, protein-, and mineral-enriched postdischarge formula.

Authors:  Monique van de Lagemaat; Joost Rotteveel; Mirjam M van Weissenbruch; Harrie N Lafeber
Journal:  Eur J Nutr       Date:  2012-12-18       Impact factor: 5.614

7.  Pediatric radiation dose and risk from bone density measurements using a GE Lunar Prodigy scanner.

Authors:  J Damilakis; G Solomou; G E Manios; A Karantanas
Journal:  Osteoporos Int       Date:  2013-01-10       Impact factor: 4.507

8.  Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors.

Authors:  S Mergler; R Rieken; D Tibboel; H M Evenhuis; R R van Rijn; C Penning
Journal:  Pediatr Radiol       Date:  2012-01-18

9.  Placental volume at 11 weeks is associated with offspring bone mass at birth and in later childhood: Findings from the Southampton Women's Survey.

Authors:  S J Woolford; E M Curtis; S D'Angelo; P Mahon; L Cooke; J K Cleal; S R Crozier; K M Godfrey; H M Inskip; C Cooper; N C Harvey
Journal:  Placenta       Date:  2020-07-22       Impact factor: 3.481

10.  Estimating the absorbed dose to critical organs during dual X-ray absorptiometry.

Authors:  M Mokhtari-Dizaji; A A Sharafi; B Larijani; N Mokhlesian; H Hasanzadeh
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

View more