Use of a mechanical microvascular anastomotic device in head and neck free tissue transfer.

M L Shindo1, P D Costantino, V P Nalbone, D H Rice, U K Sinha.   

Abstract

BACKGROUND: The use of mechanical microvascular anastomotic systems for free tissue transfer has previously been reported. Currently, a commercially available coupling device (3M Healthcare, St. Paul, Minn) is widely used for various microvascular free flaps. However, to our knowledge, there are no reports in the literature describing the efficacy of this particular device in regard to free tissue transfer in head and neck reconstruction.
OBJECTIVE: To describe the surgical technique, limitations, and guidelines for application of this system for vascular anastomosis in head and neck free tissue transfer.
DESIGN: The microvascular anastomotic device was used in 79 head and neck free flaps: radial forearm (n = 28), rectus abdominis (n = 27), fibula (n = 12), lateral thigh (n = 4), iliac crest (n = 3), gracilis (n = 2), jejunum (n = 1), pectoral (n = 1), and lateral arm (n = 1). Follow-up ranged from 6 months to 2.5 years.
SETTING: Two major teaching/referral medical centers. PARTICIPANTS: Seventy-six patients ranging in age from 19 to 86 years. INTERVENTION: A total of 105 anastomoses (17 arterial and 88 venous) were performed. OUTCOME MEASURES: Anastomotic times and patency rates were evaluated.
RESULTS: the anastomotic times ranged from 8 to 18 minutes for the arteries (average, 10 minutes) and from 4 to 16 minutes for the veins (average, 5 minutes). None of the flaps resulted in venous congestion due to thrombosis at the anastomosis. Two arterial anastomoses resulted in thrombosis, one of which was detected intra-operatively and successfully salvaged with conventional suture anastomosis.
CONCLUSIONS: The patency rates with the microvascular anastomotic system appear to compare favorably with those of standard suture techniques. The major advantage is that the time of venous anastomosis is reduced, thereby decreasing the total ischemic time. An additional advantage is the ease with which anastomoses can be performed when the vessels are deep within a wound, where suture placement is difficult.

Entities:  

Mesh:

Year:  1996        PMID: 8615971     DOI: 10.1001/archotol.1996.01890170063012

Source DB:  PubMed          Journal:  Arch Otolaryngol Head Neck Surg        ISSN: 0886-4470


  7 in total

1.  Use of a microvascular coupler for repair of major distal upper extremity artery injuries.

Authors:  G G Hallock; D C Rice
Journal:  J Hand Microsurg       Date:  2009-07-10

Review 2.  Systematic review of microvascular coupling devices for arterial anastomoses in free tissue transfer.

Authors:  Abhijit R Gundale; Yuro J Berkovic; Payam Entezami; Cherie-Ann O Nathan; Brent A Chang
Journal:  Laryngoscope Investig Otolaryngol       Date:  2020-07-18

3.  End-to-end versus end-to-side venous microanastomoses in head and neck reconstruction.

Authors:  Cesare Piazza; Valentina Taglietti; Alberto Paderno; Piero Nicolai
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-04-21       Impact factor: 2.503

4.  [The ring-pin anastomosis technique. Long-term clinical experiences with the mechanical ring-pin system for microvascular anastomoses in reconstructive head and neck surgery ].

Authors:  E Röpke; A Berghaus; M Bloching
Journal:  HNO       Date:  2004-02       Impact factor: 1.284

5.  The utility of the microvascular anastomotic coupler in free tissue transfer.

Authors:  Amandeep S Grewal; Boban Erovic; Nick Strumas; Danny J Enepekides; Kevin M Higgins
Journal:  Can J Plast Surg       Date:  2012

6.  Meta-analysis of arterial anastomosis techniques in head and neck free tissue transfer.

Authors:  Yu-Jing Wang; Xiu-Ling Wang; Shan Jin; Ran Zhang; Yu-Qin Gao
Journal:  PLoS One       Date:  2021-04-01       Impact factor: 3.240

Review 7.  Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?

Authors:  D D Krijgh; B Tellier; T Teunis; W Maarse; J H Coert
Journal:  JPRAS Open       Date:  2021-08-11