Literature DB >> 8601769

In vitro evaluation of the accuracy of several electronic apex locators.

R J Czerw1, M S Fulkerson, J C Donnelly, J O Walmann.   

Abstract

This study describes two tests of the in vitro accuracy of several models of electronic canal length measuring devices (ECLMDs) using a gelatin test model and extracted human teeth with fully formed apices. In part 1, four previously untested ECLMDs were used in dry canals after access and pulpectomy. File lengths with wth file tip just visible at the foramen were compared to ECLMD lengths. Clinically significant ECLMD measurements of > or + 0.5 mm than visual length were noted with two ECLMDs 16.6% and 10% of the time. The other two ECLMDs had no measurements >0.5 mm than the visual measurement. The gelatin test model proved highly accurate with 4 of 6 ECLMDs tested thus far. Part 2 compared the accuracy of a previously tested ECLMD using the gelatin model when taking length measurements with canals both dry and wet with distilled water in them. There was no difference between measurements in wet or dry canals. Irrigation with distilled water may be a clinical aid when using resistance ECLMDs.

Entities:  

Mesh:

Year:  1995        PMID: 8601769     DOI: 10.1016/S0099-2399(06)80988-X

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Root canal length measurement in teeth with electrolyte compensation.

Authors:  K C Nam; S C Kim; S J Lee; Y J Kim; N G Kim; D W Kim
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  In vitro evaluation of the accuracy of two electronic apex locators.

Authors:  Viresh Chopra; Shibani Grover; S Datta Prasad
Journal:  J Conserv Dent       Date:  2008-04

3.  Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  J Paras Mull; Vinutha Manjunath; Mk Manjunath
Journal:  J Conserv Dent       Date:  2012-04

4.  Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph-In Vitro Study.

Authors:  Okba Mahmoud; Mawada Hassan Awad Abdelmagied; Ahmad Hisham Dandashi; Bakr Nssaief Jasim; Hussam Alddin Tawfik Kayali; Saaid Al Shehadat
Journal:  Int J Dent       Date:  2021-05-04

5.  Influence of calcium hydroxide residues after using different irrigants on the accuracy of two electronic apex locators: An in vitro study.

Authors:  Nooshin Sadat Shojaee; Zahra Zaeri; Mohammad Mehdi Shokouhi; Fereshteh Sobhnamayan; Alireza Adl
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

6.  Comparison between two methods of working length determination and its effect on radiographic extent of root canal filling: a clinical study [ISRCTN71486641].

Authors:  L Smadi
Journal:  BMC Oral Health       Date:  2006-02-11       Impact factor: 2.757

7.  An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.

Authors:  Kalyan Vinayak Chakravarthy Pishipati
Journal:  Iran Endod J       Date:  2013-08-01

8.  Effects of dissolving solutions on the accuracy of an electronic apex locator-integrated endodontic handpiece.

Authors:  Yakup Ustun; Ozgur Uzun; Ozgur Er; Murat Maden; Fatma Yalpı; Burhan Can Canakci
Journal:  ScientificWorldJournal       Date:  2013-11-26

9.  Comparison of Accuracy in Determining the Root Canal Working Length by Using Two Generations of Apex Locators - An In Vitro Study.

Authors:  Kapil Golvankar; Mohammed Abdul Kader; Abhilash Abdul Latheef; Ahamed Babiker Mohammed Ali; Shahabe Saquib Abullais; Mohammed Sibagathullah
Journal:  Open Access Maced J Med Sci       Date:  2019-09-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.