Literature DB >> 12043801

Root canal length measurement in teeth with electrolyte compensation.

K C Nam1, S C Kim, S J Lee, Y J Kim, N G Kim, D W Kim.   

Abstract

Electronic root canal length measurement devices have made it easier and faster to measure the root canal length of a tooth compared with the conventional radiographic method. Of these electronic apex locators, the frequency-dependent type features greater accuracy and convenience in operation. However, its accuracy is still influenced by the presence of blood and/or the various electrolytes used in root canal therapy. This study describes the development of a new frequency-dependent electronic apex locator featuring electrolyte compensation, utilising an impedance ratio and voltage difference technique to minimise the influence of electrolytes on the accuracy of root canal length measurement. The errors for distances from file tips to apical constrictions were determined in vivo with the device operating with electrolyte compensation. The measured lengths were compared with the true lengths of the extracted teeth determined using a microscope. The mean error was +0.14+/-0.27mm, and 95.2% of the measurements were within the clinical tolerance of +/-0.5mm. It was also found that the degree of accuracy was not dependent on the size of the apical foramen (p = 0.74).

Mesh:

Substances:

Year:  2002        PMID: 12043801     DOI: 10.1007/bf02348125

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

1.  Development of a frequency-dependent-type apex locator with automatic compensation.

Authors:  D W Kim; K C Nam; S J Lee
Journal:  Crit Rev Biomed Eng       Date:  2000

2.  Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K-file and the root canal irrigants.

Authors:  T Saito; Y Yamashita
Journal:  Dent Jpn (Tokyo)       Date:  1990

3.  An evaluation of the Apex Locator Endocater.

Authors:  N J McDonald; E J Hovland
Journal:  J Endod       Date:  1990-01       Impact factor: 4.171

4.  Apex locators in endodontics: which, when and how?

Authors:  B S Chong; T R Pitt Ford
Journal:  Dent Update       Date:  1994-10

5.  An in vivo comparison of gradient and absolute impedance electronic apex locators.

Authors:  R Lauper; F Lutz; F Barbakow
Journal:  J Endod       Date:  1996-05       Impact factor: 4.171

6.  An in vivo evaluation of Root ZX electronic apex locator.

Authors:  S Shabahang; W W Goon; A H Gluskin
Journal:  J Endod       Date:  1996-11       Impact factor: 4.171

7.  Electronic ohmmeter. An electronic device for the determination of the root canal length.

Authors:  R V Suchde; S T Talim
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1977-01

8.  A clinical evaluation of electronic root canal measurement.

Authors:  L J O'Neill
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1974-09

9.  An in vivo comparative study of two apex locators.

Authors:  A Pallarés; V Faus
Journal:  J Endod       Date:  1994-12       Impact factor: 4.171

10.  In vitro evaluation of the accuracy of several electronic apex locators.

Authors:  R J Czerw; M S Fulkerson; J C Donnelly; J O Walmann
Journal:  J Endod       Date:  1995-11       Impact factor: 4.171

View more
  2 in total

1.  In vivo assessment of the impedance ratio method used in electronic foramen locators.

Authors:  Marcos V H Rambo; Humberto R Gamba; Gustavo B Borba; Joaquim M Maia; Carlos A S Ramos
Journal:  Biomed Eng Online       Date:  2010-09-06       Impact factor: 2.819

2.  Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An In Vitro Study.

Authors:  Masoud Saatchi; Shiva Iravani; Mehrdad Akhavan Khaleghi; Amin Mortaheb
Journal:  Iran Endod J       Date:  2017
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.