Influence of materials and geometry on fields produced by cochlear electrode arrays.

H A Ruddy1, G E Loeb.   

Abstract

Most cochlear prostheses use multichannel electrode arrays implanted in the scala tympani to generate multiple parallel channels of activity in the tonotopically mapped auditory nerve. Various materials and geometrical arrangements of contacts and locations within the scala tympani have been used, resulting in substantial differences in the required stimulus strengths and resulting spatial distributions of neural activity. Activated iridium (AIR) permits systematic adjustment of its metal-electrolyte interface properties by changing the degree of electrochemical activation. Planar equivalent models of bipolar cochlear electrode geometries using iridium have been built, and their impedance magnitude and phase versus frequency for various degrees of activation have been characterised. The electrical fields produced at various distances from bipolar contacts in saline are measured. In comparison to platinum and unactivated iridium, AIR provides a much lower metal-electrolyte interfacial impedance. When two AIR contacts are placed with their edges close together, the resulting field distributions are determined largely by the high (but safe) current densities at their apposed edges rather than the overall extent of the contacts. These edge effects permit a novel design for a bipolar array that produces N channels of radially distributed, non-overlapping fields and that requires only N + 1 contacts.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8558952     DOI: 10.1007/bf02523011

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Long-term measures of electrode impedance and auditory thresholds for the Ineraid cochlear implant.

Authors:  M F Dorman; L M Smith; K Dankowski; G McCandless; J L Parkin
Journal:  J Speech Hear Res       Date:  1992-10

2.  Better speech recognition with cochlear implants.

Authors:  B S Wilson; C C Finley; D T Lawson; R D Wolford; D K Eddington; W M Rabinowitz
Journal:  Nature       Date:  1991-07-18       Impact factor: 49.962

3.  In vitro measurement and characterization of current density profiles produced by non-recessed, simple recessed, and radially varying recessed stimulating electrodes.

Authors:  M F Suesserman; F A Spelman; J T Rubinstein
Journal:  IEEE Trans Biomed Eng       Date:  1991-05       Impact factor: 4.538

4.  Charge-injection densities of iridium and iridium-ion-implanted Ti-6A1-4V with relevancy to neural stimulation.

Authors:  I S Lee; R A Buchanan; J M Williams
Journal:  J Biomed Mater Res       Date:  1991-08

5.  Acute and long-term ventricular stimulation thresholds with a new, iridium oxide-coated electrode.

Authors:  A G Del Bufalo; J Schlaepfer; M Fromer; L Kappenberger
Journal:  Pacing Clin Electrophysiol       Date:  1993-06       Impact factor: 1.976

6.  The impedance of stainless-steel electrodes.

Authors:  L A Geddes; C P Da Costa; G Wise
Journal:  Med Biol Eng       Date:  1971-09

7.  Speech discrimination in deaf subjects with cochlear implants.

Authors:  D K Eddington
Journal:  J Acoust Soc Am       Date:  1980-09       Impact factor: 1.840

8.  Design and fabrication of an experimental cochlear prosthesis.

Authors:  G E Loeb; C L Byers; S J Rebscher; D E Casey; M M Fong; R A Schindler; R F Gray; M M Merzenich
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

9.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies.

Authors:  B Onaral; H P Schwan
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

10.  Chronic animal testing of new cardiac pacing electrodes.

Authors:  S Adler; P Spehr; J Allen; W Block
Journal:  Pacing Clin Electrophysiol       Date:  1990-12       Impact factor: 1.976

View more
  2 in total

1.  Finite element analysis of a floating microstimulator.

Authors:  Mesut Sahin; Syed S Ur-Rahman
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2007-06       Impact factor: 3.802

2.  Psychophysical and physiological measures of electrical-field interaction in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.