Literature DB >> 1874521

In vitro measurement and characterization of current density profiles produced by non-recessed, simple recessed, and radially varying recessed stimulating electrodes.

M F Suesserman1, F A Spelman, J T Rubinstein.   

Abstract

Potential fields induced by nonrecessed, simple recessed, and radially varying recessed electrode designs were measured in vitro. Comparison of experimental results with theoretical analyses substantiated the experimental measurement technique and emphasized the importance of considering both nonuniform charge injection and surface electrochemistry when designing implantable stimulating electrodes. Radially varying recesses produced uniform charge injection at the electrode surface and at the aperture-tissue interface. In general, the radially varying recessed electrodes provided a combination of uniform charge injection and flexibility in design and fabrication that warrants their incorporation into all appropriate planar stimulating electrode designs.

Mesh:

Year:  1991        PMID: 1874521     DOI: 10.1109/10.81558

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  19 in total

1.  Resolution of the epiretinal prosthesis is not limited by electrode size.

Authors:  Matthew R Behrend; Ashish K Ahuja; Mark S Humayun; Robert H Chow; James D Weiland
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2011-04-19       Impact factor: 3.802

2.  It's the little things: On the complexity of planar electrode heating in MRI.

Authors:  Johannes B Erhardt; Thomas Lottner; Jessica Martinez; Ali C Özen; Martin Schuettler; Thomas Stieglitz; Daniel B Ennis; Michael Bock
Journal:  Neuroimage       Date:  2019-03-29       Impact factor: 6.556

3.  Finite element analysis of a floating microstimulator.

Authors:  Mesut Sahin; Syed S Ur-Rahman
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2007-06       Impact factor: 3.802

4.  Design of electrodes and current limits for low frequency electrical impedance tomography of the brain.

Authors:  O Gilad; L Horesh; D S Holder
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

5.  Factors affecting perceptual thresholds in epiretinal prostheses.

Authors:  Chloé de Balthasar; Sweta Patel; Arup Roy; Ricardo Freda; Scott Greenwald; Alan Horsager; Manjunatha Mahadevappa; Douglas Yanai; Matthew J McMahon; Mark S Humayun; Robert J Greenberg; James D Weiland; Ione Fine
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-06       Impact factor: 4.799

6.  Frequency-domain reconstruction of signals in electrical bioimpedance spectroscopy.

Authors:  Aleksander S Paterno; Rodrigo A Stiz; Pedro Bertemes-Filho
Journal:  Med Biol Eng Comput       Date:  2009-10       Impact factor: 2.602

7.  Safety assessment of epidural wire electrodes for cough production in a chronic pig model of spinal cord injury.

Authors:  Krzysztof E Kowalski; Tomasz Kowalski; Anthony F DiMarco
Journal:  J Neurosci Methods       Date:  2016-05-07       Impact factor: 2.390

8.  Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording.

Authors:  Felix Deku; Yarden Cohen; Alexandra Joshi-Imre; Aswini Kanneganti; Timothy J Gardner; Stuart F Cogan
Journal:  J Neural Eng       Date:  2018-02       Impact factor: 5.379

9.  Brightness as a function of current amplitude in human retinal electrical stimulation.

Authors:  Scott H Greenwald; Alan Horsager; Mark S Humayun; Robert J Greenberg; Matthew J McMahon; Ione Fine
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-07-15       Impact factor: 4.799

10.  Form-function relations in cone-tipped stimulating microelectrodes.

Authors:  Steve Yaeli; Einat Binyamin; Shy Shoham
Journal:  Front Neuroeng       Date:  2009-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.