Literature DB >> 8550654

Tendon-healing to cortical bone compared with healing to a cancellous trough. A biomechanical and histological evaluation in goats.

P St Pierre1, E J Olson, J J Elliott, K C O'Hair, L A McKinney, J Ryan.   

Abstract

This study was performed to test the hypothesis that attaching a tendon to a trough in cancellous bone results in tendon-healing that is biomechanically superior to that after direct fixation of a tendon to cortical bone. Twenty adult female goats were treated with a bilateral tenotomy of the infraspinatus tendon with subsequent reattachment of the tendon. In shoulders randomized to the cancellous-fixation group, a cancellous bed was prepared with a motorized burr and a template measuring twenty by five by five millimeters. The repair in the shoulders randomized to the cortical-fixation group was performed in the same manner, except that the tendon was attached to cortical bone. Three outcome measures were assessed, six and twelve weeks after the repair, with the Student paired t test and analysis of variance: load to failure, energy to failure, and stiffness. The types of repair were not significantly different with regard to any of the three outcomes. When the six and twelve-week data were combined, an average difference in load to failure of 3.9 per cent in favor of cancellous repair was observed but it was not significant (p = 0.78). The associated 95 per cent confidence interval for the difference ranged from 10.5 per cent in favor of cortical repair to 18.3 per cent in favor of cancellous repair. Histological analysis at six and twelve weeks revealed progressive maturation and reorganization of the bone-tendon interface with re-establishment of collagen-fiber continuity between the tendon and bone. This process was indistinguishable between the cortical and cancellous specimens. This study demonstrated no significant benefit from the creation of a trough to expose the tendon to cancellous bone. In this model, at both six and twelve weeks, the tendon-to-bone healing process of the two groups appeared similar and the biomechanical properties were approximately equal.

Entities:  

Mesh:

Year:  1995        PMID: 8550654     DOI: 10.2106/00004623-199512000-00010

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  33 in total

1.  Gene transfer to the tendon-bone insertion site.

Authors:  Christian Lattermann; Boris A Zelle; Janey D Whalen; Axel W A Baltzer; Paul D Robbins; Christopher Niyibizi; Christopher H Evans; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-09       Impact factor: 4.342

2.  Biology and augmentation of tendon-bone insertion repair.

Authors:  Ppy Lui; P Zhang; Km Chan; L Qin
Journal:  J Orthop Surg Res       Date:  2010-08-21       Impact factor: 2.359

Review 3.  [Clinical management of rotator cuff tears. Current concepts in cell-based therapy strategies].

Authors:  A Ficklscherer; M F Pietschmann; M Bendiks; B P Roßbach; P E Müller
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

Review 4.  Where tendons and ligaments meet bone: attachment sites ('entheses') in relation to exercise and/or mechanical load.

Authors:  M Benjamin; H Toumi; J R Ralphs; G Bydder; T M Best; S Milz
Journal:  J Anat       Date:  2006-04       Impact factor: 2.610

5.  Long-term morphology of a healing bone-tendon interface: a histological observation in the sheep model.

Authors:  R Newsham-West; H Nicholson; M Walton; P Milburn
Journal:  J Anat       Date:  2007-03       Impact factor: 2.610

6.  Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction.

Authors:  Krzysztof Gaweda; Jacek Walawski; Robert Wegłowski; Wojciech Krzyzanowski
Journal:  Int Orthop       Date:  2007-12-07       Impact factor: 3.075

7.  Assessment of the canine model of rotator cuff injury and repair.

Authors:  Kathleen A Derwin; Andrew R Baker; Michael J Codsi; Joseph P Iannotti
Journal:  J Shoulder Elbow Surg       Date:  2007-06-08       Impact factor: 3.019

8.  Mini-open incision for distal biceps repair by suture anchors: follow-up of eighteen patients.

Authors:  L Pangallo; A Valore; L Padovani; G Coratella; F Schena; B Magnan; R Adani
Journal:  Musculoskelet Surg       Date:  2015-04-23

Review 9.  The enthesis: a review of the tendon-to-bone insertion.

Authors:  John Apostolakos; Thomas Js Durant; Corey R Dwyer; Ryan P Russell; Jeffrey H Weinreb; Farhang Alaee; Knut Beitzel; Mary Beth McCarthy; Mark P Cote; Augustus D Mazzocca
Journal:  Muscles Ligaments Tendons J       Date:  2014-11-17

10.  Differences in tendon graft healing between the intra-articular and extra-articular ends of a bone tunnel.

Authors:  Asheesh Bedi; Sumito Kawamura; Liang Ying; Scott A Rodeo
Journal:  HSS J       Date:  2008-12-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.