Angioplasty pressure-volume measurement.

A Murray1, V Allen.   

Abstract

An instrument has been developed for controlled inflation and deflation of an angioplasty balloon. The mean difference between inflation to 800 kPa in air and a simulated coronary artery is 71.2 kPa. The repeatability of four inflation/deflation cycles is 6.4 kPa with the balloon in air and 9.0 kPa in the simulated artery.

Mesh:

Year:  1995        PMID: 8523924     DOI: 10.1007/bf02510800

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Regional differences in elastic recoil after percutaneous transluminal coronary angioplasty: a quantitative angiographic study.

Authors:  B J Rensing; W R Hermans; B H Strauss; P W Serruys
Journal:  J Am Coll Cardiol       Date:  1991-05       Impact factor: 24.094

2.  Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation.

Authors:  C E Hjemdahl-Monsen; J A Ambrose; S Borrico; M Cohen; W Sherman; D Alexopoulos; R Gorlin; V Fuster
Journal:  J Am Coll Cardiol       Date:  1990-09       Impact factor: 24.094

Review 3.  Restenosis after coronary angioplasty: review of the literature.

Authors:  B Meier
Journal:  Eur Heart J       Date:  1988-03       Impact factor: 29.983

4.  In vivo assessment of vascular dilatation during percutaneous transluminal coronary angioplasty.

Authors:  A Jain; L L Demer; A E Raizner; C J Hartley; J M Lewis; R Roberts
Journal:  Am J Cardiol       Date:  1987-11-01       Impact factor: 2.778

5.  Transluminal dilatation of coronary-artery stenosis.

Authors:  A Gruntzig
Journal:  Lancet       Date:  1978-02-04       Impact factor: 79.321

6.  Restenosis after coronary angioplasty: the paradox of increased lumen diameter and restenosis.

Authors:  K J Beatt; P W Serruys; H E Luijten; B J Rensing; H Suryapranata; P de Feyter; M van den Brand; G J Laarman; J Roelandt
Journal:  J Am Coll Cardiol       Date:  1992-02       Impact factor: 24.094

  6 in total
  1 in total

1.  Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments.

Authors:  A Murray; V Allen; M K Bennett
Journal:  Heart       Date:  1998-06       Impact factor: 5.994

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.