Literature DB >> 2968251

Restenosis after coronary angioplasty: review of the literature.

B Meier1.   

Abstract

The average restenosis rate reported so far in the literature is just below 30%. Although restenosis correlates well with the recurrence of symptoms, the two factors are not identical. The incidence of myocardial infarction during the first 2 years after coronary angioplasty is 4% and the incidence of death is 2%. These two cardiac events are rarely the first symptom of restenosis. Restenosis, therefore, is not primarily a life threatening disease but still deserves prompt evaluation and correction. Restenosis is stenosis-related rather than patient-related. Thus, restenosis rate per patient increases with the number of lesions or arteries treated. Restenosis rates vary considerably with centres. Serial analyses of restenosis rates at individual centres revealed that the restenosis rates remained constant at a centre-specific level. Differences in case selection and particularities in data definition and analysis may account for both these observations. There is no sound evidence that procedural factors (balloon size, number, duration, or pressure of inflations, etc.) or drug regimens are capable of reducing the recurrence rate. All risk factors for restenosis identified so far are difficult to influence. Extinguishable factors such as smoking seem of little importance in this particular problem. Efforts to find ways of reducing restenoses after coronary angioplasty are commendable and necessary. Their chance of success, however, is small. 'Old customers' will continue to represent 20-30% of the clientele for coronary angioplasty. Their risk for failure and complications is small, but they do carry a considerable risk of restenosis.

Entities:  

Mesh:

Year:  1988        PMID: 2968251     DOI: 10.1093/eurheartj/9.suppl_c.1

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  3 in total

1.  Dynamics of Vascular Remodeling: An Overview and Bibliography.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1996       Impact factor: 2.300

2.  Angioplasty pressure-volume measurement.

Authors:  A Murray; V Allen
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

3.  Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments.

Authors:  A Murray; V Allen; M K Bennett
Journal:  Heart       Date:  1998-06       Impact factor: 5.994

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.