Regional differences in elastic recoil after percutaneous transluminal coronary angioplasty: a quantitative angiographic study.

B J Rensing1, W R Hermans, B H Strauss, P W Serruys.   

Abstract

The immediate result of percutaneous transluminal coronary angioplasty is influenced by both plastic and elastic changes of the vessel wall. To evaluate the amount of elastic recoil after coronary balloon angioplasty, the minimal luminal cross-sectional area of the largest balloon used at highest inflation pressure was compared with the minimal luminal vessel cross-sectional area directly after final balloon deflation in 607 lesions (526 patients). Elastic recoil was defined as the difference between balloon cross-sectional area and minimal luminal cross-sectional area of the dilated coronary segment immediately after balloon withdrawal. A videodensitometric analysis technique was used to avoid geometric assumptions on stenosis morphology directly after angioplasty. Mean balloon cross-sectional area was 5.3 +/- 1.6 mm2 and minimal luminal cross-sectional area after angioplasty was 2.8 +/- 1.4 mm2. Reference areas before and after angioplasty did not differ (6.0 +/- 2.6 and 6.2 +/- 2.6 mm2, respectively). Univariate analysis revealed that asymmetric lesions, lesions located in less angulated parts of the artery and lesions with a low plaque content showed more elastic recoil. Lesions located in distal parts of the coronary tree were also associated with more elastic recoil probably related to relative balloon oversizing in these distal lesions.

Entities:  

Mesh:

Year:  1991        PMID: 2016480     DOI: 10.1016/0735-1097(91)90936-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  Proliferative response of human and minipig smooth muscle cells after coronary angioplasty to growth factors and platelets.

Authors:  C Unterberg; T Meyer; V Wiegand; H Kreuzer; A B Buchwald
Journal:  Basic Res Cardiol       Date:  1996 Nov-Dec       Impact factor: 17.165

2.  Angioplasty pressure-volume measurement.

Authors:  A Murray; V Allen
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

3.  Vascular Response to Experimental Stent Malapposition and Under-Expansion.

Authors:  Caroline C O'Brien; Augusto C Lopes; Kumaran Kolandaivelu; Mie Kunio; Jonathan Brown; Vijaya B Kolachalama; Claire Conway; Lynn Bailey; Peter Markham; Marco Costa; James Ware; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2016-01-05       Impact factor: 3.934

4.  Comparison of Paclitaxel-Coated Balloon Treatment and Plain Old Balloon Angioplasty for De Novo Coronary Lesions.

Authors:  Ae Young Her; Soe Hee Ann; Gillian Balbir Singh; Yong Hoon Kim; Sang Yong Yoo; Scot Garg; Bon Kwon Koo; Eun Seok Shin
Journal:  Yonsei Med J       Date:  2016-03       Impact factor: 2.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.