Differences in spectral composition between monostrut Bjork-Shiley and Carbomedics valves implanted in the aortic position.

H P Sava1, J T McDonnell.   

Abstract

The paper investigates the differences in spectral composition between monostrut Bjork-Shiley and Carbomedics valves implanted in the aortic position using a modified overdetermined forward-backward Prony's method. Spectral composition of the closing sounds produced by these two valves are compared in terms of the e number of spectral components and their relative energy. Results show that, for both valves, the major spectral components are concentrated below 2 kHz. In the case of the Carbomedics valve, it is found that 97% of the total energy lies below 120 Hz where the sensitivity of the human auditory system is poor. This is one of the main reasons why the Carbomedics valve is acoustically quieter than a monostrut Bjork-Shiley valve when in operation. In addition, a clear difference monostrut and Carbomedics valves has also been found in the 400 Hz-2 kHz sub-band. A distinct difference between normal and malfunctioning cases of each prostheses has been found in the frequency components beyond 400 Hz. In the malfunctioning cases the frequency components in that region move to the lower regions of the spectrum and a large part of the energy is concentrated between 250 and 400 Hz.

Entities:  

Mesh:

Year:  1995        PMID: 8523911     DOI: 10.1007/bf02510787

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Acoustic analysis of the closing sounds of bileaflet prosthetic valves in a sheep model.

Authors:  R L Donnerstein; W A Scott; A Vasu; J G Copeland
Journal:  J Thorac Cardiovasc Surg       Date:  1991-06       Impact factor: 5.209

2.  A comparison of the noise sensitivity of nine QRS detection algorithms.

Authors:  G M Friesen; T C Jannett; M A Jadallah; S L Yates; S R Quint; H T Nagle
Journal:  IEEE Trans Biomed Eng       Date:  1990-01       Impact factor: 4.538

3.  Use of the fast Fourier transform in the frequency analysis of the second heart sound in normal man.

Authors:  A P Yoganathan; R Gupta; F E Udwadia; W H Corcoran; R Sarma; R J Bing
Journal:  Med Biol Eng       Date:  1976-07

Review 4.  Phonocardiogram signal analysis: a review.

Authors:  R M Rangayyan; R J Lehner
Journal:  Crit Rev Biomed Eng       Date:  1987

5.  Heart-sound processing by average and variance calculation--physiologic basic and clinical implications.

Authors:  R Beyar; S Levkovitz; S Braun; Y Palti
Journal:  IEEE Trans Biomed Eng       Date:  1984-09       Impact factor: 4.538

6.  A quantitative method for the in vitro study of sounds produced by prosthetic aortic heart valves. Part I: Analytical considerations.

Authors:  D W Suobank; A P Yoganathan; E C Harrison; W H Corcoran
Journal:  Med Biol Eng Comput       Date:  1984-01       Impact factor: 2.602

7.  Improved phonocardiogram system based on acoustic impedance matching.

Authors:  R S Schwartz; J T Reeves; I E Sodal; F S Barnes
Journal:  Am J Physiol       Date:  1980-04

8.  Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.

Authors:  A Moritz; U Steinseifer; G Kobinia; K Neuwirth-Riedl; H Wolters; H Reul; E Wolner
Journal:  Br Heart J       Date:  1992-06

9.  Physical analysis of the Björk-Shiley prosthetic valve sound.

Authors:  F Schöndube; H Keusen; B J Messmer
Journal:  J Thorac Cardiovasc Surg       Date:  1983-07       Impact factor: 5.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.