Acoustic analysis of the closing sounds of bileaflet prosthetic valves in a sheep model.

R L Donnerstein1, W A Scott, A Vasu, J G Copeland.   

Abstract

Previous investigations of mechanical valve sounds have shown that (1) frequency spectra of sounds produced by abnormal valves differ from those of properly functioning valves and (2) leaflets of normally functioning bileaflet valves do not close synchronously. This investigation studied effects of mechanical valve size, environment, and hemodynamic state on closing sounds. A single 25 mm bileaflet mitral mechanical valve was implanted in six sheep and a single 27 mm valve in four sheep. With digital signal processing, asynchronous leaflet closure and frequency spectra were assessed after alterations in animal position, respiratory phase, heart rate, afterload, contractility, and preload. Both asynchronous leaflet closure and frequency spectra varied among animals, and, except for a decrease in asynchrony with increasing contractility, were largely independent of valve size and hemodynamics. Baseline asynchrony ranged from 0.5 to 4.2 msec. Frequency spectra were characterized by the first three resonant peaks. Lowest resonant peaks ranged from 2.5 to 3.4 kHz, middle from 4.7 to 6.8 kHz, and highest from 7.2 to 9.6 kHz. These results indicate that accurate assessment of mechanical valve function with acoustic analysis requires baseline studies in all patients by means of a system with a frequency response of more than 10 kHz.

Entities:  

Mesh:

Year:  1991        PMID: 2038199

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  Comparison of two spike areas in bileaflet mechanical valve closing sound.

Authors:  Hiroshi Sugiki; Suguru Kubota; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2012-05-25       Impact factor: 1.731

2.  Wavelet analysis of bileaflet mechanical valve sounds.

Authors:  Hiroshi Sugiki; Norihiko Shiiya; Toshifumi Murashita; Takashi Kunihara; Kenji Matsuzaki; Takehiro Kubota; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

3.  New automated wavelet analytical system with a cellular phone for recording intercellular phone remote transmitted bileaflet valve sound.

Authors:  Takashi Sugiki; Hiroshi Sugiki; Norihiko Shiiya; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2009-12-25       Impact factor: 1.731

4.  Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve.

Authors:  Hiroshi Sugiki; Toshifumi Murashita; Norihiko Shiiya; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

5.  Differences in spectral composition between monostrut Bjork-Shiley and Carbomedics valves implanted in the aortic position.

Authors:  H P Sava; J T McDonnell
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.