Literature DB >> 8514547

Concept of dose nonuniformity in interstitial brachytherapy.

C B Saw1, N Suntharalingam, A Wu.   

Abstract

PURPOSE: Evaluation of the 3-dimensional dose distributions of interstitial implants using the dose uniformity ratio. METHODS AND MATERIALS: Single source, two sources, three and four sources arranged both linearly and in the form of a triangle or a square, ribbons with different seed spacings, a single-plane and double-plane implants were evaluated. The evaluations involved the use of differential dose volume histograms and the dose nonuniformity ratio defined as the ratio of the high dose volume to the reference volume.
RESULTS: For a single source, the dose nonuniformity is the same regardless which dose rate is selected as the treatment dose rate. For any multi-source implant, the dose nonuniformity is altered depending on the selection of the reference dose rate. In addition, the dose nonuniformity curve exhibited three characteristics zones.
CONCLUSION: The dose nonuniformity ratio can be a useful tool in assessing and optimizing interstitial implants.

Mesh:

Year:  1993        PMID: 8514547     DOI: 10.1016/0360-3016(93)90971-w

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  15 in total

1.  Quality assessment of interstitial implants in high- dose- rate brachytherapy after lumpectomy in patients of early stage breast cancer.

Authors:  Samrat Dutta; Suresh C Sharma; Rajinder Singh; Rakesh Kapoor; Arun S Oinam; Anoop Bhardwaj; Pradeep Goswami
Journal:  Indian J Surg Oncol       Date:  2011-03-24

Review 2.  The Role of Brachytherapy in the Treatment of Breast Cancer.

Authors:  Daniela Kauer-Dorner; Daniel Berger
Journal:  Breast Care (Basel)       Date:  2018-05-29       Impact factor: 2.860

3.  Dosimetric Superiority of High-Dose-Rate (HDR) Brachytherapy Using a Surface Mold Applicator for Primary Cutaneous Angiosarcoma of the Scalp.

Authors:  Kei Takase; Tomohiro Itonaga; Ryuji Mikami; Ryokichi Irisawa; Kazuhiro Saito
Journal:  Cureus       Date:  2022-05-16

4.  Dosimetric comparison of manual forward planning with uniform dwell times versus volume-based inverse planning in interstitial brachytherapy of cervical malignancies.

Authors:  Siddanna R Palled; Nikhila K Radhakrishna; Senthil Manikantan; Hashmath Khanum; Bindu K Venugopal; Lokesh Vishwanath
Journal:  Rep Pract Oncol Radiother       Date:  2020-09-11

5.  Dosimetric comparison of Acuros™ BV with AAPM TG43 dose calculation formalism in breast interstitial high-dose-rate brachytherapy with the use of metal catheters.

Authors:  Mourougan Sinnatamby; Vivekanandan Nagarajan; Sathyanarayana Reddy K; Gunaseelan Karunanidhi; Vivekanandam Singhavajala
Journal:  J Contemp Brachytherapy       Date:  2015-09-14

6.  MITHRA - multiparametric MR/CT image adapted brachytherapy (MR/CT-IABT) in anal canal cancer: a feasibility study.

Authors:  Luca Tagliaferri; Stefania Manfrida; Brunella Barbaro; Maria Maddalena Colangione; Valeria Masiello; Gian Carlo Mattiucci; Elisa Placidi; Rosa Autorino; Maria Antonietta Gambacorta; Silvia Chiesa; Giovanna Mantini; György Kovács; Vincenzo Valentini
Journal:  J Contemp Brachytherapy       Date:  2015-10-19

7.  Assessment of dose homogeneity in conformal interstitial breast brachytherapy with special respect to ICRU recommendations.

Authors:  Tibor Major; Georgina Fröhlich; Csaba Polgar
Journal:  J Contemp Brachytherapy       Date:  2011-09-30

8.  Qualitative dosimetric and radiobiological evaluation of high - dose - rate interstitial brachytherapy implants.

Authors:  Than S Kehwar; Syed F Akber; Kamlesh Passi
Journal:  Int J Med Sci       Date:  2008-02-19       Impact factor: 3.738

9.  A brachytherapy plan evaluation tool for interstitial applications.

Authors:  Surega Anbumani; N Arunai Nambiraj; Sridhar Dayalan; Kalaivany Ganesh; Pichandi Anchineyan; Ramesh S Bilimagga
Journal:  Adv Bioinformatics       Date:  2014-02-09

10.  Dose optimization in gynecological 3D image based interstitial brachytherapy using martinez universal perineal interstitial template (MUPIT) -an institutional experience.

Authors:  Pramod Kumar Sharma; Praveen Kumar Sharma; Jamema V Swamidas; Umesh Mahantshetty; D D Deshpande; Jayanand Manjhi; D V Rai
Journal:  J Med Phys       Date:  2014-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.