Literature DB >> 8504234

Effect of immobilization and configuration on lumbar adjacent-segment biomechanics.

K Y Ha1, M J Schendel, J L Lewis, J W Ogilvie.   

Abstract

The motion and facet load changes at the adjacent segment after lumbosacral immobilization (with different angles) were quantified in vitro using canine spines. Changes were examined under flexion, extension, and lateral bending. An increase (extension: 62%; flexion: 85%; left bend: 30%; right bend 26%) in motion at the adjacent segment was found for all motions after immobilization. Adjacent-segment facet load remained constant under any load state or immobilized configuration. For all configurations, the facet contact site impinged in extension, remained unchanged in left bending, and moved superiorly in right bending. This study has shown that after immobilization the facet contact patterns at the adjacent segment changed, load was unchanged, and segmental motion increased when the lumbar spine reproduced the same range of motion. The configuration of the immobilized segments had no effect on these changes.

Entities:  

Mesh:

Year:  1993        PMID: 8504234

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  25 in total

1.  Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.

Authors:  Derek P Lindsey; Ali Kiapour; Scott A Yerby; Vijay K Goel
Journal:  Int J Spine Surg       Date:  2015-11-13

2.  A prospective randomised study on the long-term effect of lumbar fusion on adjacent disc degeneration.

Authors:  Per Ekman; Hans Möller; Adel Shalabi; Yiang Xiao Yu; Rune Hedlund
Journal:  Eur Spine J       Date:  2009-04-01       Impact factor: 3.134

Review 3.  Proximal junctional kyphosis and failure-diagnosis, prevention, and treatment.

Authors:  Ngoc-Lam M Nguyen; Christopher Y Kong; Robert A Hart
Journal:  Curr Rev Musculoskelet Med       Date:  2016-09

4.  Kinetic magnetic resonance imaging analysis of lumbar segmental motion at levels adjacent to disc herniation.

Authors:  Lifeng Lao; Michael D Daubs; Shinji Takahashi; Elizabeth L Lord; Jeremiah R Cohen; Guibin Zhong; Jeffrey C Wang
Journal:  Eur Spine J       Date:  2015-04-29       Impact factor: 3.134

Review 5.  Unilateral versus bilateral pedicle screw fixation in short-segment lumbar spinal fusion: a meta-analysis of randomised controlled trials.

Authors:  Zengfeng Xin; Weixu Li
Journal:  Int Orthop       Date:  2015-07-15       Impact factor: 3.075

6.  Biomechanical effects of pedicle screw fixation on adjacent segments.

Authors:  Thein Aung Kyaw; Zhuo Wang; Toshihiko Sakakibara; Takamasa Yoshikawa; Tadashi Inaba; Yuichi Kasai
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-22

Review 7.  Adjacent Segment Pathology after Lumbar Spinal Fusion.

Authors:  Jae Chul Lee; Sung-Woo Choi
Journal:  Asian Spine J       Date:  2015-09-22

8.  Which radiographic parameters are linked to failure of a dynamic spinal implant?

Authors:  Eike Hoff; Patrick Strube; Antonius Rohlmann; Christian Gross; Michael Putzier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

9.  Thoracic disc herniation of the adjacent segment with acutely progressing myelopathy.

Authors:  In-Soo Oh; Jun-Yeong Seo; Kee-Yong Ha; Yoon-Chung Kim
Journal:  Asian Spine J       Date:  2010-04-26

10.  Risk factors for adjacent segment disease after lumbar fusion.

Authors:  Choon Sung Lee; Chang Ju Hwang; Sung-Woo Lee; Young-Joon Ahn; Yung-Tae Kim; Dong-Ho Lee; Mi Young Lee
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.