Pulmonary deposition of a nebulised aerosol during mechanical ventilation.

S H Thomas1, M J O'Doherty, H M Fidler, C J Page, D F Treacher, T O Nunan.   

Abstract

BACKGROUND: There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation.
METHODS: Nine male patients were studied during mechanical ventilation after open heart surgery and two experiments were performed in each to determine the reproducibility of the method. A solution of technetium-99m labelled human serum albumin (99mTc HSA (50 micrograms); activity in experiment 1, 74 MBq; in experiment 2, 185 MBq) in 3 ml saline was administered with a Siemens Servo 945 nebuliser system (high setting) and a System 22 Acorn nebuliser unit. Pulmonary deposition was quantified by means of a gamma camera and corrections derived from lung phantom studies.
RESULTS: Pulmonary aerosol deposition was completed in 22 (SD 4) minutes. Total pulmonary deposition (% nebuliser dose (SD)) was 2.2 (0.8)% with 1.5% and 0.7% depositing in the right and left lungs respectively; 0.9% of the nebuliser activity was detected in the endotracheal tube or trachea and 51% was retained within the nebuliser unit. Considerable variability between subjects was found for total deposition (coefficient of variation (CV) 46%), but within subject reproducibility was good (CV 15%).
CONCLUSIONS: Administration of aerosol in this way is inefficient and further research is needed to find more effective alternatives in patients who require mechanical respiratory support. This method of measurement seems suitable for the assessment of new methods of aerosol delivery in these patients.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8493630      PMCID: PMC464293          DOI: 10.1136/thx.48.2.154

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  18 in total

1.  Evaluation of bronchodilator responsiveness in mechanically ventilated patients.

Authors:  P C Gay; J R Rodarte; M Tayyab; R D Hubmayr
Journal:  Am Rev Respir Dis       Date:  1987-10

2.  Pulmonary deposition of nebulised pentamidine isethionate: effect of nebuliser type, dose, and volume of fill.

Authors:  M O'Doherty; S Thomas; C Page; C Bradbeer; T Nunan; N Bateman
Journal:  Thorax       Date:  1990-06       Impact factor: 9.139

3.  Effect of ipratropium bromide aerosol on respiratory function in patients under ventilator treatment.

Authors:  T Wegener; S Wretman; B Sandhagen; S O Nyström
Journal:  Acta Anaesthesiol Scand       Date:  1987-10       Impact factor: 2.105

4.  Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients. Comparison of dose to the lungs.

Authors:  H D Fuller; M B Dolovich; G Posmituck; W W Pack; M T Newhouse
Journal:  Am Rev Respir Dis       Date:  1990-02

5.  Comparison of plasma concentrations of aerosolized pentamidine in nonventilated and ventilated patients with pneumocystosis.

Authors:  P M Girard; B Clair; A Certain; R Bidault; S Matheron; B Regnier; R Farinotti
Journal:  Am Rev Respir Dis       Date:  1989-12

6.  Does inhalation of pentamidine in the supine position increase deposition in the upper part of the lung?

Authors:  M J O'Doherty; S H Thomas; C J Page; C Bradbeer; T O Nunan; N T Bateman
Journal:  Chest       Date:  1990-06       Impact factor: 9.410

7.  Aerosol delivery to the rabbit lung with an infant ventilator.

Authors:  M Flavin; M MacDonald; M Dolovich; G Coates; H O'Brodovich
Journal:  Pediatr Pulmonol       Date:  1986 Jan-Feb

8.  Deposition of carbenicillin aerosols in cystic fibrosis: effects of nebuliser system and breathing pattern.

Authors:  S P Newman; G Woodman; S W Clarke
Journal:  Thorax       Date:  1988-04       Impact factor: 9.139

9.  Aerosol deposition in the human lung: effect of high-frequency oscillation on the deposition characteristics of an inhaled nebulized aerosol.

Authors:  S H Thomas; J A Langford; R J George; D M Geddes
Journal:  Clin Sci (Lond)       Date:  1988-11       Impact factor: 6.124

10.  Does 99Tcm human serum albumin alter the characteristics of nebulized pentamidine isethionate?

Authors:  M J O'Doherty; S Thomas; C Page; A R Clark; D Mitchell; E Heduan; T O Nunan; N T Bateman
Journal:  Nucl Med Commun       Date:  1989-07       Impact factor: 1.690

View more
  13 in total

Review 1.  Nebuliser therapy in childhood.

Authors:  P W Barry; C O'Callaghan
Journal:  Thorax       Date:  1997-04       Impact factor: 9.139

Review 2.  Nebuliser therapy in the intensive care unit.

Authors:  M J O'Doherty; S H Thomas
Journal:  Thorax       Date:  1997-04       Impact factor: 9.139

3.  A retrospective comparison of inhaled milrinone and iloprost in post-bypass pulmonary hypertension.

Authors:  Kassiani Theodoraki; Apostolos Thanopoulos; Panagiota Rellia; Evangelos Leontiadis; Dimitrios Zarkalis; Konstantinos Perreas; Theophani Antoniou
Journal:  Heart Vessels       Date:  2017-07-17       Impact factor: 2.037

Review 4.  Inhaled Antibiotics for Gram-Negative Respiratory Infections.

Authors:  Eric Wenzler; Dustin R Fraidenburg; Tonya Scardina; Larry H Danziger
Journal:  Clin Microbiol Rev       Date:  2016-07       Impact factor: 26.132

Review 5.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12

6.  Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask.

Authors:  S N Parkes; A D Bersten
Journal:  Thorax       Date:  1997-02       Impact factor: 9.139

Review 7.  The pulmonary physician in critical care . 12: Acute severe asthma in the intensive care unit.

Authors:  P Phipps; C S Garrard
Journal:  Thorax       Date:  2003-01       Impact factor: 9.139

Review 8.  The delivery of aerosolized steroids from MDIs with nozzle extensions: quantitative laboratory evaluation of a method to improve aerosol delivery to intubated patients.

Authors:  D Hess; D Fisher; R A Peterfreund; R M Kacmarek
Journal:  Intensive Care Med       Date:  1995-11       Impact factor: 17.440

9.  Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

Authors:  C J Harvey; M J O'Doherty; C J Page; S H Thomas; T O Nunan; D F Treacher
Journal:  Thorax       Date:  1995-01       Impact factor: 9.139

10.  Intravenous sulforhodamine B reduces alveolar surface tension, improves oxygenation, and reduces ventilation injury in a respiratory distress model.

Authors:  You Wu; Tam L Nguyen; Carrie E Perlman
Journal:  J Appl Physiol (1985)       Date:  2020-11-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.