Abstract

Oesophageal, rectal, bladder, tympanic and pulmonary artery sites are used intraoperatively to measure body temperature. However, the temperatures measured at each site have different physiological and practical importance. The present two-part study sought to compare liquid crystal (CR) skin temperature with other temperature monitors which are used routinely during surgery. The first part compared CR with oesophageal (OS) temperature during general inhalational anaesthesia. The second part compared CR with OS, pulmonary artery (PA), and bladder (BL) temperatures during the periods of rapid temperature change associated with cardiopulmonary bypass (CPB). During the first part, the mean difference between OS and CR was -0.14 +/- 0.85 degrees C; this difference remained consistent over time (P < 0.05 by repeated measures analysis of variance). During the second part, the difference in temperature readings between CR and each of the other monitors remained consistent except for CR vs PA and CR vs OS during the cooling period of CPB, when the iced cardioplegia slush directly affected the PA and OS temperatures. This study suggests that CR, an inexpensive and noninvasive means of temperature monitoring, reflects trends in temperature changes in the clinical setting.

Entities:  

Mesh:

Year:  1993        PMID: 8485798     DOI: 10.1007/BF03009638

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  11 in total

1.  Does forehead liquid crystal temperature accurately reflect "core" temperature?

Authors:  G C Allen; J C Horrow; H Rosenberg
Journal:  Can J Anaesth       Date:  1990-09       Impact factor: 5.063

Review 2.  Body temperature and anaesthesia.

Authors:  G M Hall
Journal:  Br J Anaesth       Date:  1978-01       Impact factor: 9.166

3.  Perforation of the tympanic membrane, a complication of tympanic thermometry during anesthesia.

Authors:  C T Wallace; W E Marks; W Y Adkins; J E Mahaffey
Journal:  Anesthesiology       Date:  1974-09       Impact factor: 7.892

4.  An evaluation of liquid-crystal thermometry as a screening device for intraoperative hyperthermia.

Authors:  D E Lees; W Schuette; J M Bull; J Whang-Peng; E R Atkinson; T E Macnamara
Journal:  Anesth Analg       Date:  1978 Nov-Dec       Impact factor: 5.108

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Liquid crystal thermometry during anaesthesia.

Authors:  S Lacoumenta; G M Hall
Journal:  Anaesthesia       Date:  1984-01       Impact factor: 6.955

7.  Pigs susceptible to energy metabolism in the fulminant hyperthermia stress syndrome.

Authors:  C H Williams; C Houchins; M D Shanklin
Journal:  Br Med J       Date:  1975-08-16

8.  The thermoregulatory threshold in humans during halothane anesthesia.

Authors:  D I Sessler; C I Olofsson; E H Rubinstein; J J Beebe
Journal:  Anesthesiology       Date:  1988-06       Impact factor: 7.892

9.  Morphine and postoperative rewarming in critically ill patients.

Authors:  J L Rodriguez; C Weissman; M C Damask; J Askanazi; A I Hyman; J M Kinney
Journal:  Circulation       Date:  1983-12       Impact factor: 29.690

10.  Continuous monitoring of skin temperature using a liquid-crystal thermometer during anesthesia.

Authors:  G E Burgess; J R Cooper; R J Marino; M J Peuler
Journal:  South Med J       Date:  1978-05       Impact factor: 0.954

View more
  1 in total

1.  Validity of devices that assess body temperature during outdoor exercise in the heat.

Authors:  Douglas J Casa; Shannon M Becker; Matthew S Ganio; Christopher M Brown; Susan W Yeargin; Melissa W Roti; Jason Siegler; Julie A Blowers; Neal R Glaviano; Robert A Huggins; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.