Literature DB >> 2208538

Does forehead liquid crystal temperature accurately reflect "core" temperature?

G C Allen1, J C Horrow, H Rosenberg.   

Abstract

Liquid crystal thermometry (LCT) is a non-invasive alternative to temperature monitoring. We evaluated the ability of forehead LCT, rectal temperature, and axillary skin temperature to trend distal oesophageal temperature during rapid warming on cardiopulmonary bypass. In 24 patients undergoing open heart surgery, temperatures were measured during the rapid warming phase on bypass (12-35 min). Scattergrams of temperature vs time for the four temperature sites each contained 150 data points. Polynomial regression analysis revealed that LCT, but not axillary or rectal temperatures, correlated with oesophageal temperature. We conclude that forehead LCT may be useful to monitor temperature trends and to detect rapid elevations in body temperature when more invasive temperature monitoring is inappropriate or unavailable.

Entities:  

Mesh:

Year:  1990        PMID: 2208538     DOI: 10.1007/BF03006486

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  12 in total

Review 1.  Body temperature and anaesthesia.

Authors:  G M Hall
Journal:  Br J Anaesth       Date:  1978-01       Impact factor: 9.166

2.  Relationship between esophageal temperature gradient and heart and lung sounds heard by esophageal stethoscope.

Authors:  R D Kaufman
Journal:  Anesth Analg       Date:  1987-10       Impact factor: 5.108

3.  Esophageal and tympanic temperature responses to core blood temperature changes during hyperthermia.

Authors:  K Shiraki; N Konda; S Sagawa
Journal:  J Appl Physiol (1985)       Date:  1986-07

4.  An evaluation of liquid-crystal thermometry as a screening device for intraoperative hyperthermia.

Authors:  D E Lees; W Schuette; J M Bull; J Whang-Peng; E R Atkinson; T E Macnamara
Journal:  Anesth Analg       Date:  1978 Nov-Dec       Impact factor: 5.108

5.  Inaccuracy of liquid crystal thermometry to identify core temperature trends in postoperative adults.

Authors:  M S Vaughan; R C Cork; R W Vaughan
Journal:  Anesth Analg       Date:  1982-03       Impact factor: 5.108

6.  Liquid crystal thermometry during anaesthesia.

Authors:  S Lacoumenta; G M Hall
Journal:  Anaesthesia       Date:  1984-01       Impact factor: 6.955

7.  Precision and accuracy of intraoperative temperature monitoring.

Authors:  R C Cork; R W Vaughan; L S Humphrey
Journal:  Anesth Analg       Date:  1983-02       Impact factor: 5.108

8.  Pigs susceptible to energy metabolism in the fulminant hyperthermia stress syndrome.

Authors:  C H Williams; C Houchins; M D Shanklin
Journal:  Br Med J       Date:  1975-08-16

9.  Halothane-induced porcine malignant hyperthermia: metabolic and hemodynamic changes.

Authors:  G A Gronert; R A Theye
Journal:  Anesthesiology       Date:  1976-01       Impact factor: 7.892

10.  Continuous monitoring of skin temperature using a liquid-crystal thermometer during anesthesia.

Authors:  G E Burgess; J R Cooper; R J Marino; M J Peuler
Journal:  South Med J       Date:  1978-05       Impact factor: 0.954

View more
  7 in total

1.  Effects of season on sleep and skin temperature in the elderly.

Authors:  Kazue Okamoto-Mizuno; Kazuyo Tsuzuki
Journal:  Int J Biometeorol       Date:  2009-12-30       Impact factor: 3.787

2.  Monitoring body-core temperature from the trachea: comparison between pulmonary artery, tympanic, esophageal, and rectal temperatures.

Authors:  J K Hayes; D J Collette; J L Peters; K W Smith
Journal:  J Clin Monit       Date:  1996-05

3.  Liquid crystal skin thermometry: an accurate reflection of core temperature?

Authors:  S J Brull; A J Cunningham; N R Connelly; T Z O'Connor; D G Silverman
Journal:  Can J Anaesth       Date:  1993-04       Impact factor: 5.063

4.  Skin Temperatures of Back or Neck Are Better Than Abdomen for Indication of Average Proximal Skin Temperature During Sleep of School-Aged Children.

Authors:  Véronique Bach; Chris R Abbiss; Jean-Pierre Libert; Susan M McCabe
Journal:  Front Psychiatry       Date:  2020-09-18       Impact factor: 4.157

5.  Validity and reliability of devices that assess body temperature during indoor exercise in the heat.

Authors:  Matthew S Ganio; Christopher M Brown; Douglas J Casa; Shannon M Becker; Susan W Yeargin; Brendon P McDermott; Lindsay M Boots; Paul W Boyd; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2009 Mar-Apr       Impact factor: 2.860

6.  Validity of devices that assess body temperature during outdoor exercise in the heat.

Authors:  Douglas J Casa; Shannon M Becker; Matthew S Ganio; Christopher M Brown; Susan W Yeargin; Melissa W Roti; Jason Siegler; Julie A Blowers; Neal R Glaviano; Robert A Huggins; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

7.  Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites.

Authors:  Hsuan-Yu Chen; Andrew Chen; Chiachung Chen
Journal:  Sensors (Basel)       Date:  2020-05-19       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.