Literature DB >> 8478653

The effect of dyshemoglobins on pulse oximetry: Part I, Theoretical approach and Part II, Experimental results using an in vitro test system.

K J Reynolds1, E Palayiwa, J T Moyle, M K Sykes, C E Hahn.   

Abstract

Pulse oximeters are known to be inaccurate in the presence of elevated concentrations of carboxyhemoglobin and methemoglobin. This paper attempts to alleviate some of the confusion that exists between fractional and functional saturation, and to clarify the comparison of each with SpO2. A series of theoretical relationships between pulse oximeter reading (SpO2) and actual oxygen saturation (both fractional and functional) is derived using simple absorption theory. The theoretical relationships are checked using an experimental in vitro test system. This consists of a blood circuit containing a model finger, capable of simulating the pulsatile transmission signals through a real finger. Theoretical predictions and experimental results are compared and are found to agree well in the presence of carboxyhemoglobin, but less well with methemoglobin. Possible reasons are discussed.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8478653     DOI: 10.1007/bf01616919

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  17 in total

1.  Response of 10 pulse oximeters to an in vitro test system.

Authors:  K J Reynolds; J T Moyle; M K Sykes; C E Hahn
Journal:  Br J Anaesth       Date:  1992-04       Impact factor: 9.166

2.  Temperature dependence of led and its theoretical effect on pulse oximetry.

Authors:  K J Reynolds; J P de Kock; L Tarassenko; J T Moyle
Journal:  Br J Anaesth       Date:  1991-11       Impact factor: 9.166

3.  Pulse oximeter desaturation due to methemoglobinemia.

Authors:  J B Eisenkraft
Journal:  Anesthesiology       Date:  1988-02       Impact factor: 7.892

4.  Benzocaine-induced methemoglobinemia in an adult: accuracy of pulse oximetry with methemoglobinemia.

Authors:  S T Anderson; J Hajduczek; S J Barker
Journal:  Anesth Analg       Date:  1988-11       Impact factor: 5.108

5.  Carboxyhemoglobin levels in American blood donors.

Authors:  R D Stewart; E D Baretta; L R Platte; E B Stewart; J H Kalbfleisch; B Van Yserloo; A A Rimm
Journal:  JAMA       Date:  1974-08-26       Impact factor: 56.272

6.  A resuscitation puzzle: acute acquired methemoglobinemia.

Authors:  K Tada; A Tokaji; Y Odaka; T Kurasako; J Mutoh; M Takatori; N Morimoto; M Matsumoto; F Kosaka
Journal:  Crit Care Med       Date:  1987-06       Impact factor: 7.598

7.  Blood carboxyhaemoglobin and cyanide levels in fire survivors.

Authors:  C J Clark; D Campbell; W H Reid
Journal:  Lancet       Date:  1981-06-20       Impact factor: 79.321

Review 8.  Pulse oximetry: technical aspects of machine design.

Authors:  J A Pologe
Journal:  Int Anesthesiol Clin       Date:  1987

9.  Methemoglobinemia.

Authors:  S Curry
Journal:  Ann Emerg Med       Date:  1982-04       Impact factor: 5.721

10.  Definition and notation of hemoglobin oxygen saturation.

Authors:  W G Zijlstra; B Oeseburg
Journal:  IEEE Trans Biomed Eng       Date:  1989-08       Impact factor: 4.538

View more
  5 in total

1.  Sensing oxygen through skin using a red diode laser and fluorescence lifetimes.

Authors:  S B Bambot; G Rao; M Romauld; G M Carter; J Sipior; E Terpetchnig; J R Lakowicz
Journal:  Biosens Bioelectron       Date:  1995       Impact factor: 10.618

2.  Measurement of blood-oxygen saturation using a photoacoustic technique in the rabbit hypoxemia model.

Authors:  Kiguna Sei; Masanori Fujita; Takeshi Hirasawa; Shinpei Okawa; Toshihiro Kushibiki; Hidenori Sasa; Kenichi Furuya; Miya Ishihara
Journal:  J Clin Monit Comput       Date:  2018-06-06       Impact factor: 2.502

3.  Methaemoglobinemia after Liposuction under Tumescent Local Anaesthesia - Diagnostic Value of Pulse Oximetry.

Authors:  Sebastian Brandt; Oliver Kimberger; Benjamin Weber; Anne Klose; Swetlana Stockmann; Wilfried Schmeller; Hartmut Gehring; Patrick Kellner
Journal:  World J Plast Surg       Date:  2022-03

Review 4.  Drug-induced methaemoglobinaemia. Treatment issues.

Authors:  M D Coleman; N A Coleman
Journal:  Drug Saf       Date:  1996-06       Impact factor: 5.606

5.  Convolutional Neural Networks for Spectroscopic Analysis in Retinal Oximetry.

Authors:  Damon T DePaoli; Prudencio Tossou; Martin Parent; Dominic Sauvageau; Daniel C Côté
Journal:  Sci Rep       Date:  2019-08-06       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.