Literature DB >> 8475309

Interpretation of CT studies: single-screen workstation versus film alternator.

D V Beard1, B M Hemminger, J R Perry, M A Mauro, K E Muller, D M Warshauer, M A Smith, A J Zito.   

Abstract

A prototype single-screen workstation with a 2,048 x 2,560-pixel high-brightness monitor, 0.11-second image display time, and simple ergonomic design was compared to a conventional horizontal film alternator in diagnostic interpretation of chest computed tomography (CT) studies. Four radiologists used either the workstation or film alternator in interpretation of studies obtained in 10 patients. A counterbalanced within-subject repeated measures experimental design was used. Response times were analyzed for both methods of interpretation. Grades of excellent, acceptable, and unacceptable were assigned by a blinded "grader" to reports of the radiologists. The average time needed for an interpretation at the workstation was 5.65 minutes. No interpretations were graded unacceptable. Retrospective power analysis showed that 16 observers rather than four would have been required to show that use of the workstation was faster than the alternator. With this 95% confidence interval, the workstation interpretation time is clinically equivalent to that with the alternator. These data show that this type of workstation has practical application in interpretation of CT, magnetic resonance imaging, and ultrasound studies.

Entities:  

Mesh:

Year:  1993        PMID: 8475309     DOI: 10.1148/radiology.187.2.8475309

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  A picture archiving and communications system featuring multiple monitors using Windows98.

Authors:  R Ernst; V T Le; A Kawashima; C Caskey; D Zelitt; E Tamm; C M Sandler
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

2.  Soft copy display requirements for digital mammography.

Authors:  Bradley M Hemminger
Journal:  J Digit Imaging       Date:  2003-12-15       Impact factor: 4.056

3.  Processes involved in reading imaging studies: workflow analysis and implications for workstation development.

Authors:  S B Gay; A H Sobel; L Q Young; S J Dwyer
Journal:  J Digit Imaging       Date:  1997-02       Impact factor: 4.056

4.  Digital chest radiography: clinical aspects.

Authors:  U Tylén
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

5.  How many screens does a CT workstation need?

Authors:  D V Beard; B M Hemminger; K M Denelsbeck; R E Johnston
Journal:  J Digit Imaging       Date:  1994-05       Impact factor: 4.056

Review 6.  Comparison of navigation techniques for large digital images.

Authors:  Bradley M Hemminger; Anne Bauers; Jian Yang
Journal:  J Digit Imaging       Date:  2008-06-27       Impact factor: 4.056

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.